Restriction: This topic applies only when a Database Connectors license has been installed via the
Micro Focus License Management System.
The following limits exist when working with MSSQL:
Maximum number of columns per key:
|
16
|
Maximum number of columns:
|
1024
|
Maximum number of bytes in a single row when using
Database Connectors for MSSQL:
|
8060
|
To achieve the same sort or retrieval sequence under MSSQL as under the file system, key fields that contain signed numeric data must be preceded by a BINARY XFD directive.
Database Connectors supports the data types shown below; when it's creating tables, the following conversion rules are used, in the sequence shown:
COBOL
|
SQL Server
|
DATE XFD directive
|
DATETIME
|
BINARY XFD directive
|
VARBINARY(n) (if SIZE < 255)
IMAGE (if SIZE >255)
|
VAR_LENGTH XFD directive
|
VARCHAR(n) (if SIZE < 255)
|
Usage FLOAT
|
REAL (if SIZE = 4)
|
Usage DOUBLE
|
FLOAT (if SIZE = 8)
|
Any other numeric usage:
PIC 9(n)V9(m)
|
SMALLINT (if m = 0 and n < 5)
INT (if m = 0 and n < 10)
DECIMAL(n + m, m)(otherwise)
|
Any other usage:
PIC X(n)
|
CHAR(n) (if n < 255)
TEXT (if n > 255)
|