The following table shows the LE general callable services that are supported by this COBOL system.
Routine |
Description |
Supported? |
CEE3DMP |
Generate dump |
No * |
CEE3PRM |
Query parameter string |
Yes |
CEE3USR |
Set/query user area fields |
Yes |
CEERAN0 |
Calculate uniform random numbers |
Yes |
CEETDLI |
Invoke IMS |
No ** |
CEETEST |
Invoke debug tool |
No * |
Note:
- Calls to unsupported routines marked by '*' are accepted but no action occurs. In the FEED_BACK condition (FC) code, the severity is set to 4, the message number to 9999, and the facility-ID to MFX.
- Calls to unsupported routines marked by '**' are not accepted and if used in a COBOL program result in the fatal run-time system error 173 ("Called program file not found in drive/directory").