Micro Focus COBOL Server 2.3 for Windows
>
Enterprise Server
>
Enterprise Server Reference
>
Error Messages
>
Enterprise Server Error Messages
>
CASCD Error Messages
>
CASCD1070 - CASCD1200
CASCD1070 - CASCD1200
Restriction:
This topic applies only when the Enterprise Server feature is enabled.
CASCD1070S
An Animserv process for Server
server-name
has abended due to an unexpected signal
signal-value
.
CASCD1071I
An administration SEP has been started for Server
server-name
CASCD1072I
An administration SEP has been started for Server
server-name
has successfully completed termination
CASCD1073S
An administration SEP for Server
server-name
has exited, the value specified on the exit call was
exit-value
CASCD1074S
An administration SEP for Server
server-name
has abended due to an unexpected signal
signal-value
.
CASCD1075I
The ES TSC Service Process has been started for Server
server-name
CASCD1076I
The ES TSC Service Process for Server
server-name
has successfully completed termination
CASCD1077S
The ES TSC Service Process for Server
server-name
has exited, the value specified on the exit call was
exit-value
CASCD1079I
A Cobremotedaemon process has been started for Server
server-name
CASCD1080I
A Cobremotedaemon process for Server
server-name
has successfully terminated
CASCD1081S
A Cobremotedaemon process for Server
server-name
has exited, the value specified on the exit call was
exit-value
CASCD1082S
A Cobremotedaemon process for Server
server-name
has abended due to an unexpected signal
signal-value
.
CASCD1083I
Enterprise Server Debug SEP created successfully.
CASCD1084I
A Debug SEP for Server
server-name
has successfully completed termination
CASCD1085S
A Debug SEP for Server
server-name
has exited, the value specified on the exit call was
exit-value
CASCD1086S
A Debug SEP for Server
server-name
has abended due to an unexpected signal
signal-value
.
CASCD1087I Cobdebugremote process created for Server server-name, process-id = pid
A Cobdebugremote process has been started for Server
server-name
.
CASCD1088S Cobdebugremote process for Server server-name abended by signal signal-value
A Cobdebugremote process for Server
server-name
has abended due to an unexpected signal
signal-value
.
CASCD1089I Cobdebugremote process for Server server-name has terminated normally
An Cobdebugremote process for Server
server-name
has successfully terminated.
CASCD1090S Cobdebugremote process for Server server-name exited with value exit-value
An Cobdebugremote process for Server
server-name
has exited, the value specified on the exit call was
exit-value
.
CASCD1200I
The transaction
transaction-id
issued a SPOOLOPEN command but did not issue a subsequent SPOOLCLOSE command before transaction termination.
Parent topic:
CASCD Error Messages