Previous Topic Next topic Print topic


Configuring Enterprise Server for WebSphere MQSeries Trigger Monitors

The Enterprise Server region must be configured for both IMS and JES. For JES, you must define a batch initiator to process “class A” jobs. You need to ensure that enough initiators are defined for the job class to run all instances of the trigger monitor plus any other submitted jobs that will run under that class.

You also need to generate a PSB for the trigger monitor and create an XA resource to allow MPP applications to interface with IBM WebSphere MQ. A sample PSB definition file, csq4trmn.psb is included in the %ProgramFiles(x86)%\Micro Focus\Studio Enterprise Edition x.x\base\source folder.

The path to the CSQ4TRMN executable must be added to the JES Program Path. The path to any IMS MPP transactions that are started by the Trigger Monitor must be present on the IMS TM Application Path.

Previous Topic Next topic Print topic