CIC-READQ-TS QUEUE(name) ... INTO(dataarea)|SET(linkdataname) ... LENGTH(dataarea) NUMITEMS(dataarea) ... [ITEM(value)|NEXT] ... [SYSID(name)] ... [ERROR(errorpara)]
ERROR (errorpara) |
User-defined error routine to perform when an abnormal condition occurs. |
INTO (dataarea) |
Name of data area where AMB places transient or temporary data. |
ITEM (value) |
Relative record number in the queue; can be a literal or COBOL data name defined as S9(04)COMP. Required with REWRITE. |
LENGTH (value) |
Maximum length of data; can be a literal (LINK or XCTL only) or COBOL data name defined as S9(04)COMP. Can also be a partial length (XCTL only). |
NEXT |
Read next sequential logical record. |
NUMITEMS (dataarea) |
Number of items in the queue. |
QUEUE(name) |
Queue name; can be a literal (maximum 8 characters), or COBOL data name (maximum 30 characters) defined as X(4). |
SET(linkdataname) |
01-level Linkage Section data area identical to the linkdataname in the associated TP-LINKAGE call. |
SYSID(name) |
Remote system name; can be a literal or a COBOL data name (maximum 4 characters). |