Restriction: This topic applies only when the AppMaster Builder AddPack has been installed, and applies only to Windows platforms.
- In Online Express, click
File >
Database Access. The Database Access Summary window appears.
- Click the call you want to customize, and click
Database Access >
Call Tailoring. The Database Call Tailoring Browser appears.
- In the
Database Action column, double-click a database action. The DB Call Tailoring Editor appears.
- Click the event you want to customize.
- From the
Action drop-down list, click the action you want to perform.
- In the
Argument field, type the appropriate argument for the event.
- Do one of the following:
- For Global Code, User Rule, or Perform, click
Action/Event >
Edit Misc User Code and type the code into your editor.
- For Local Code, click
Edit Code and type the code into your editor.
- Save the code and exit the editor.
- If you want to override the default Error flag processing:
- In the
Status Matrix group using the drop-down list provided for each flag, change a default status flag from
Normal or
Error to
Exception.
- Follow steps
4 through
8 of this procedure for the
Exeption Status event and code your own error routine.
- If you want to prevent the Error flag from aborting the program, uncheck
Abort On Error.
- If you want to override the Online Express-generated error messages that show which type of call failed and which record caused the failure:
- In the
Error Message field, either type a text message or a rule name.
- From the
Error Message Type drop-down list, click either
Text or
Rule, depending on what you typed in the
Error Message field.
- Click
Apply to save your call customizations.
Note: Be sure when you specify Global Code or a User Rule that the code or the rule appears as an object on the
Project Explorer in your Globals folder.