Micro Focus Enterprise Developer 3.0 for Eclipse
>
Deployment
>
Configuration and Administration
>
Enterprise Server Reference
>
Error Messages
>
Enterprise Server Error Messages
>
CASMQ Error Messages
>
CASMQ5080 - CASMQ5088
CASMQ5080 - CASMQ5088
CASMQ5080I ES MQ Queue Manager authorized
The named queue manager is currently designated as the default queue manager.
CASMQ5081E ES MQ Queue Manager queue-manager-name connection for listener listener-name failed, reason: reason-code
ES was unable to connect to or identify the named queue manager.
CASMQ5082I ES MQ start for Listener MQ-Queue for MQ-Queue-Manager failed - owned by another thread
The ES MQ Start request targets a listener that has another thread attached.
CASMQ5083I ES MQ Listener MQ-Queue% for MQ-Queue-Manager stopped by "CSQ4TRMN:STOP" message
The ES MQ Service Process has been stopped by an MQ message containing the text "CSQ4TRMN:STOP".
CASMQ5084E ES MQ Writer for queue-name (queue manager queue-manager-name) open failed, reason: failure-reason
The MQ Service Process failed to open the
queue-name
queue.
CASMQ5085E ES MQ Writer writer-name for queue-name failed, reason: failure-reason
The MQ Service Process failed to write to the
queue-name
queue.
CASMQ5086E ES MQ trigger message for queue queue-name (listener listener-name) application application-id (type application-type) cannot be started
The ES MQ Service Process cannot start the
application-id
application of type
application-type
specified in the MQ trigger message that references queue
queue-name
. The listener
listener-name
received this trigger message.
CASMQ5087E ES MQ message from queue queue-name (listener listener-name type listener-type) not a valid trigger message
An invalid trigger message was received.
CASMQ5088I ES MQ service process (PID:process-id) recovery initiated
The IMS TM Control Process has been restarted after a failure and the new process is recovering pending requests to the previous server process (PID:
process-id
).
Parent topic: