LS - series
- LS0001W Unrecognized command-line parameter "parameter string"
- Description: Invalid command line syntax was detected.
- System action: Operation terminates
- User response: Correct the command line and try again
- Module: seelistener
- LS0006I Response received for:
session id
- Description: A response for the given session id was received.
- System action: none
- User response: none
- Module: seelistener
- LS0007I Worker thread starting for
protocol on port
port
- Description: The worker thread for the given protocol and port was started.
- System action: none
- User response: none
- Module: seelistener
- LS0008E Unable to create protocol handler:
exception message
- Description: An exception occurred.
- System action: none
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0009W Port configuration in seelistener.exe.config ignored as option '-region' specified
- Description: The port configuration in the configuration file was overridden by the -region parameter. The listener will listen on its default ports and send all requests to the specified region.
- System action: none
- User response: none
- Module: seelistener
- LS0014E An exception occurred:exception message
- Description: An exception occurred.
- System action: Operation terminates
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0017I
protocol name Listener starting on port
port number ,
- Description: A listener is starting on the given port for the specified protocol.
- System action: none
- User response: none
- Module: seelistener
- LS0019E Exception in protocol handler:
exception message
- Description: An exception occurred.
- System action: Operation terminates
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0020I SEE listener shutting down
- Description: The listener is shutting down.
- System action: none
- User response: none
- Module: seelistener
- LS0021W The "-was" option is ignored if "-dispatcher:URL" is specified.
- Description: Invalid command line syntax was detected.
- System action: Operation terminates
- User response: Correct the command line and try again
- Module: seelistener
- LS0023I
conversation type listener channel closing
- Description: The specified listener channel is closing.
- System action: none
- User response: none
- Module: seelistener
- LS0024E A
exception type exception occurred while submitting a console message to region
region name:
exception message The message was:
console message that could not be submitted
- Description: An exception occurred.
- System action: Operation terminates
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0025W TN3270 conversation
conversation ID: Discarding NVT data from client
- Description: The client sent non-3270 data, which is currently not supported. The data has been discarded.
- System action: none
- User response: none
- Module: seelistener
- LS0026E TN3270 conversation
conversation ID: Illegal sequence in TN3270E header (x'FF0:X2')
1 = invalid byte in hex
- Description: A TN3270 protocol error occurred.
- System action: The conversation is terminated
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0027E TN3270 conversation
conversation ID : Negotiation failed (description of negotiation stage), terminating conversation
- Description: TN3270 negotiation failed.
- System action: The conversation is terminated
- User response: none
- Module: seelistener
- LS0028E
protocol name conversation
conversation ID: Unexpected exception (description of where exception occurred)
exception message
- Description: An exception occurred.
- System action: Operation terminates
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0030W Invalid value
invalid heartbeat value specified for heartbeat ignored
- Description: An invalid value was specified during a heartbeat request.
- System action: Operation terminates
- User response: none
- Module: seelistener
- LS0033E
protocol name conversation
conversation ID: unable to send data: conversation ended
- Description: A protocol error for the specified protocol occurred.
- System action: The conversation is terminated.
- User response: none
- Module: seelistener
- LS0034E
protocol name conversation
conversation ID: Transaction insert exception:
exception message
- Description: An exception occurred.
- System action: Operation terminates
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0035I Shutdown initiated
- Description: The listener has been asked to shut down.
- System action: Listener is terminating
- User response: none
- Module: seelistener
- LS0036E
protocol name conversation
conversation ID: exception receiving data:
exception message
- Description: An exception occurred.
- System action: Operation terminates
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0037E
protocol name conversation
conversation ID: exception sending data:
exception message
- Description: An exception occurred.
- System action: Operation terminates
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0039E Unable to process configuration file "filename"
- Description: The specified configuration file could not be processed.
- System action: Operation terminates
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0040W Channel "channel name" has an invalid
attribute name attribute - skipping it
- Description: An error in the configuration has been detected.
- System action: none
- User response: Fix the configuration file
- Module: seelistener
- LS0041E Service installation failed:
exception
- Description: An exception occurred.
- System action: Operation terminates
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0042E Service uninstallation failed:exception
- Description: An exception occurred.
- System action: Operation terminates
- User response: Check the console log and
category of the Windows event log for further information to help resolve the problem
- Module: seelistener
- LS0043I Listener service installed
- Description: The listener service was installed.
- System action: none
- User response: none
- Module: seelistener
- LS0044I Listener service uninstalled
- Description: The listener service was uninstalled.
- System action: none
- User response: none
- Module: seelistener
- LS0045E Invalid parameter for service installation "command-line parameter"
- Description: Invalid command line syntax was detected.
- System action: Operation terminates
- User response: Correct the command line and try again
- Module: seelistener
- LS0046E -service_username and -service_password must be specified with -service_account:user
- Description: Invalid command line syntax was detected.
- System action: Operation terminates
- User response: Correct the command line and try again
- Module: seelistener
- LS0047E -service_username and -service_password are only allowed with -service_account:user
- Description: Invalid command line syntax was detected.
- System action: Operation terminates
- User response: Correct the command line and try again
- Module: seelistener
- LS0048W Unable to create Windows event log source for the listener service:
details
- Description: The listener could not create a Windows event log source to emit events to.
- System action: Events will not be logged to the event log
- User response: Make a note of any details, and attempt to rectify the problem
- Module: seelistener
- LS0049E
protocol name
conversation
conversation ID internal error:
description
- Description: An error occurred in the specified conversation.
- System action: The conversation is terminated
- User response: Make a note of the error, and attempt to fix it
- Module: seelistener
- LS0050W TN3270 conversation
conversation ID: Unsupported TN3270E data type
data type value - discarding record
- Description: An invalid TN3270 data type was received in the conversation.
- System action: the data is discarded
- User response: none
- Module: seelistener
- LS0051W TN3270 conversation
conversation ID: Unsupported TN3270 command
command code ignored
- Description: An invalid TN3270 command was received in the specified conversation.
- System action: the command is ignored
- User response: none
- Module: seelistener
- LS0052I TN3270 conversation
conversation ID: Rejecting invalid device type "device type string"
- Description: An invalid device type was received in the conversation.
- System action: The device type is rejected
- User response: none
- Module: seelistener
- LS0053W TN3270 conversation
conversation ID: Negotiation error (description of error), continuing
- Description: An error was detected during negotiation.
- System action: the error is ignored
- User response: none
- Module: seelistener
- LS0054I TN3270 conversation
conversation ID: Received
"DO", "DON'T", "WILL", or "WON'T" for unrecognized option
option code, replying with
"WON'T" or "DON'T"
- Description: An unrecognized option code was received.
- System action: none
- User response: none
- Module: seelistener
- LS0055W
protocol name conversation
conversation ID timed out waiting for client
- Description: A protocol timeout occurred.
- System action: none
- User response: none
- Module: seelistener
- LS0056W TN3270 conversation
conversation ID: Discarding
data length bytes of non-record outbound data
- Description: the specified number of bytes was discarded in the conversation.
- System action: Bytes are discarded
- User response: none
- Module: seelistener
- LS0057E
protocol name conversation
conversation ID: Terminal autoinstall failed
message
- Description: The terminal auto install failed.
- System action: The conversation with the client is terminated
- User response: Make a note of the error message and attempt to rectify based on its content
- Module: seelistener
- LS0058I
protocol conversation
conversation number (termid "terminal id") on channel "channel name" from
client address
- Description: Information about a conversation. This message may be displayed before other messages about the conversation, to identify the client system and other parameters.
- System action: none
- User response: Make note of the message if you are investigating other issues related to the listener
- Module: seelistener
- LS0059W TN3270 conversation
conversation ID: Proceeding with invalid device type "device type string"
- Description: An invalid device type was detected.
- System action: Processing continues
- User response: none
- Module: seelistener
- LS0060E Unexpected null response encountered
- Description: An unexpected null response was detected.
- System action: none
- User response: none
- Module: seelistener