Follow the steps in the topic
To define an XA resource (XAR) for an enterprise server region using the following properties:
- For one-phase commit transactions
-
ID
|
MQXA
|
Name
|
MQSERIES
|
Module
|
DFHEIBMQ
|
Open string
|
TPM=ESCICS,AXLIB=casaxlib,QMNAME=queue manager name
|
Enabled
|
checked
|
Example
TPM=CICS,AXLIB=casaxlib,QMNAME=TESTQ,CHANNEL_TESTQ,TCP,123.10.20.135(1414)
- For two-phase commit transactions
-
ID
|
MQXA
|
Name
|
MQSERIES
|
Module
|
ESMQXA
|
Open string
|
TPM=CICS,AXLIB=casaxlib,QMNAME=queue manager name, CHANNEL, TRPTYPE, CONNAME
- TPM
- The transaction manager being used. Must be set to
CICS.
- AXLIB
- The name of the library that contains the transaction manager's
ax_reg and
ax_unreg functions. Must be set to
casaxlib.
- QMNAME
- The name of the queue manager. This is a mandatory parameter.
- CHANNEL
- Optional - the name of an MQI channel. If this parameter is supplied, the CONNAME parameter must also be supplied.
- TRPTYPE
- Optional - the communications protocol for the MQI channel. The default is TCP. The following are valid values:
- LU62
- SNA LU 6.2
- NETBIOS
- NetBIOS
- SPX
- IPX/SPX
- TCP
- TCP/IP
- CONNAME
- Optional - the network address of the queue manager (connection name). The valid values of this parameter depend on the value of the TRPTYPE parameter.
If TRPTYPE is set to:
|
CONNAME must be:
|
LU62
|
A symbolic destination name, which identifies a CPI-C side information entry.
You cannot use the network qualified name of a partner LU or a partner LU alias.
|
NETBIOS
|
A NetBIOS name.
|
SPX
|
A 4-byte network address, a 6-byte node address, and an optional 2-byte socket number.
These values must be specified in hexadecimal notation. A period must separate the network and node addresses, and any socket number must be enclosed in parentheses. For example:
0a0b0c0d.804abcde23a1(5e86)
The default value is 5e86.
|
TCP
|
A host name or an IP address, optionally followed by a port number in parentheses. The default value is 1414.
|
If this parameter is supplied, the CHANNEL parameter must also be supplied.
Example Open String
TPM=CICS,AXLIB=casaxlib,QMNAME=TESTQ,CHANNEL_TESTQ,TCP,123.10.20.135(1414)
Note: If you specify the CHANNEL, TRPTYPE, and CONNAME parameters, you must also set the
MQSERVER environment variable, providing the same parameter values. See
WebSphere MQ-Specific Environment Variables for more information.
|
Enabled
|
checked
|