Allows the specification, in tenths of seconds, of the maximum time out period that will be used with any LSC style application, such as Drag and Drop, SourceConnect, or the Monitor. The default is 2 minutes (1200), and the maximum value that can be used is 2,147,483,647.
SET CCITIMEOUT=2400
Filename for and trace output and the trace options. The trace options are as follows:
Logs the details of CCI API calls to the trace file. The default condition for this option is OFF, unless a filename or any other trace option are specified, in which case it is always ON.
logs the details of protocol level calls to the trace file. If this flag is not ON, then only the details of the CCI user level API will be traced. If this flag is ON, the level of function tracing may be greatly increased. The default condition for this option is OFF.
Logs the contents of all buffers passed to and from the CCI functions. The default condition for this option is OFF. Data tracing may not be allowed if the application has been coded to prohibit data tracing for security reasons.
Specifies non-standard behavior for HIGHLIGHT and LOWLIGHT clauses used with ACCEPT and DISPLAY statements. It provides compatibility with earlier COBOL products. You should avoid using it wherever possible as support might be discontinued at some future date.
A value in the range 0 through 7. It can be one of the following values, or a cumulative value; for example, specifying a value of 6 would result in the behavior described for values 4 and 2.
Provides standard, default behavior.
When a COBOL program displays text subject to a HIGHLIGHT or LOWLIGHT clause, the run-time system uses respectively the bold or dim mode specified in the terminfo entry for the terminal. If the bold or dim mode is not specified, then the HIGHLIGHT or LOWLIGHT clause respectively has no effect.
When a COBOL program displays text subject to a HIGHLIGHT clause, the run-time system uses the bold mode. The run-time system uses the default mode for normal text. Specifying dim mode in the terminfo entry for the terminal has no affect. The LOWLIGHT clause has no effect.
High and low intensity space characters are not assumed to be the same as normal mode space characters.
Provides compatibility with default behavior of products before COBOL version 3.2.
When a COBOL program displays text subject to a HIGHLIGHT clause, the effect depends on whether the dim mode is specified in the terminfo entry for the terminal. If dim mode is specified, then the run-time system uses the default mode for highlighted text and the dim mode for normal text. If the dim mode is not specified, then the run-time system uses the bold mode for highlighted text and default mode for normal text. The LOWLIGHT clause has no effect, giving the same appearance as normal text.
Specifies the maximum elapsed time, in tenths of a second, for the connected terminal to transmit any valid escape sequence to the run-time system.
Specifies the name of a print spooler that is to receive, via its standard input stream (stdin), output from any DISPLAY UPON PRINTER statement.
COBSES={option[filename]}..., where option can be one or more of the following:
A list of the runtime switches to set or unset.
CICS honors the CMDSEC option defined in a transaction's resource definition. CICS calls its command security checking routine only when CMDSEC(YES) is specified in a transaction resource definition.
CICS overrides the CMDSEC option, and always calls its command security checking routine to issue the appropriate call to the SAF interface.
Example: ES_ESM_IDPW_CASE=UM - a single authentication is tried with the user ID folded to uppercase, and the password used as-is.
The RLS security setting of a transaction will be honored. That is, resource level security checking is performed only when the RLS security checkbox is marked in the PCT definition.
CICS processing always performs resource level security checking irrespective of the RLS security setting on the transaction definition.
This variable only applies to the region within an Enterprise Server Cluster designated as the GLM.
ES_IMS_MESGQ=[ds-file-name];max-blocks;buffer-count;start-control;[cushion-size]
Determines whether the PL/I program converts the PCB address list from a direct to an indirect addressing technique. Set the variable to one of the following:
All job messages will be sent to the Output queue, but will only actually print (either physically or logically) if the MSGCLASS of the job matches one of the sysout classes defined to an active printer.
[ES-Environment] ES_TMC_AGGREGATE={[,N|,D]|nnn,Y}
Once a thread reaches a key transactional point and requests a flush, TM waits the specified interval to accumulate subsequent threads that also request a flush. At the end of the interval, one flush is performed for all accumulated requests thus potentially improving performance by reducing the number of flush commands issued to the operating system.
ES_XA_????_NB_RETRIES= nnnn where:
If this environment variable is set, when an error occurs on a call to XA, the server recycles the SEP and attempts to reconnect to the Resource Manager. The ES_XA_????_NB_RETRIES variable specifies the number of XA call failures allowed before the SEP is recycled and the switch disabled.
Specifies the directory or directories for the UNIX system, Cob and the run-time system to search for shared libraries and callable shared objects. It must be set to include $COBDIR/lib on all platforms, except AIX (which uses LIBPATH). It should also include any directories that contain callable shared objects used by your application.
MF_MVSJOB=<lower value>{-|+}<upper value>Where:
set MF_MVSJOB=00010+00100This resets the values to start with job number 10 and run through to job number 100. When the upper limit has been reached you receive a message:
All job numbers in the range 00010:00100 are in useAt this point you need to remove some jobs from the spool - you can use the spool housekeeping functions to do this.
Country code | Language |
---|---|
AUTOMATIC | Operating system default |
AUTO | Operating system default |
DEFAULT | US English |
0031 | Dutch |
0033 | French |
0034 | Spanish |
0039 | Italian |
0043 | German (Austrian) |
0044 | UK English |
0045 | Danish |
0046 | Swedish |
0047 | Norwegian |
0049 | German |
0066 | Thai Extended |
0081 | *Japanese Katakana Extended |
0082 | *Korean |
0086 | *Simplified Chinese |
0351 | Portuguese |
0358 | Finnish |
0437 | US English |
0500 | International (Latin 1) |
0886 | *Traditional Chinese |
0939 | *Japanese Latin Extended |
9122 | *Japanese Katakana |
Character sets marked with an asterisk (*) are capable of mixed single-byte and double-byte character conversion.
A code between 2000 and 9999 (except 9122) corresponds to a user-defined translation table. User-defined tables are created using the Codecomp utility.
Specifies the record length for the REXX EXECIO command when reading or writing a line sequential file that has been cataloged with a record length of zero.