Restriction:
- This routine is supported for native COBOL only.
- This routine is not supported when CHARSET"EBCDIC" is in effect.
Reads a string of characters from the screen.
Syntax:
call "CBL_READ_SCR_CHARS" using screen-position
character-buffer
string-length
returning status-code
Parameters
-
screen-position
- Group predefined as
cblt-screen-position containing:
01 cblt-screen-position typedef.
03 cblte-scrp-row cblt-x1-compx. *> pic x comp-x.
03 cblte-scrp-col cblt-x1-compx. *> pic x comp-x.
-
character-buffer
- Call prototype (see
Key): pic x (n).
- Picture: pic x (n).
-
string-length
- Call prototype (see
Key): cblt-x2-compx.
- Picture: pic x(2) comp-x.
-
status-code
- See
Library Routines - Key.
On Entry:
screen-position
|
The screen position to start reading at. The top left corner is row 0, column 0. See
Screen Routines.
|
string-length
|
The length of the string to read.
|
On Exit:
character-buffer
|
The characters read from the screen. This data item must be at least as long as specified by
string-length; positions in it beyond that length are unchanged.
|
string-length
|
If the end of the screen is reached, the length read is returned in here.
|