Returns a named property value for an emitter.
Restriction: This routine is not currently supported in COBOL for JVM.
Syntax:
call "CBL_CTF_EMITTER_PROPERTY_GET" using by value flags
by reference emitter-name
by reference property-name
by reference property-vallen
by reference property-value
returning status-code
Parameters:
|
Using call prototype (see
Key)
|
Picture
|
flags
|
cblt-x4-comp5
|
pic x(4) comp-5
|
emitter-name
|
pic x(n)
|
pic x(n)
|
property-name
|
pic x(n)
|
pic x(n)
|
property-vallen
|
cblt-x4-comp5
|
pic x(4) comp-5
|
property-value
|
pic x(n)
|
pic x(n)
|
status-code
|
See
Library Routines - Key
|
|
On Entry:
-
flags
- Control flags:
- Bit 0
-
Value
|
Meaning
|
0
|
Return a string value. Use bit 1 to determine the string terminator.
|
1
|
Return an integer value. Ignore bit 1.
|
- Bit 1
-
Value
|
Meaning
|
0
|
Return the value as a space-terminated string.
|
1
|
Return the value as a null-terminated string.
|
- Bits 2-27
- Reserved for future use. Must be 0.
- Bit 28
-
Value
|
Meaning
|
0
|
emitter-name is space-terminated.
|
1
|
emitter-name is null-terminated.
|
- Bit 29
-
Value
|
Meaning
|
0
|
property-name is space-terminated.
|
1
|
property-name is null-terminated.
|
- Bits 30-31
- Reserved for future use. Must be 0.
-
emitter-name
- Space- or null-terminated (depending on the setting of bit 28) case-insensitive emitter name.
-
property-name
- Space- or null-terminated (depending on the setting of bit 29) case-insensitive property whose value is to be returned.
-
property-vallen
- Length of the
property-value buffer in which the property's value is to be returned. The routine will fail if the buffer is too small for the value to
be returned.
property-vallen is ignored if the value is being returned as an integer.
-
property-value
- If set to null, specifies that the routine is to return (in
property-vallen) the length of the buffer required in to hold the property specified by
property-name.
On Exit:
-
property-vallen
- Length of returned string value in the
property-value buffer, not including the termination character. If
property-value is null, or if the specified buffer length is too small for the value to be returned,
property-vallen is set to the required buffer length.
property-vallen is not set if the value is being returned as an integer.
-
property-value
- Buffer in which the property value is to be returned. This is either a pic x(n) field for a value being returned as a string,
or a pic x(4) comp-5 field for a value being returned as an integer.
-
status-code
- One of:
- 78-CTF-RET-BUFFER-TOO-SMALL
- 78-CTF-RET-EMITTER-NOT-FOUND
- 78-CTF-RET-NOT-ENOUGH-MEMORY
- 78-CTF-RET-PROPERTY-NOT-FOUND
- 78-CTF-RET-SUCCESS
- 78-CTF-RET-VALUE-NOT-INTEGER
Example:
Get two property values associated with the "myemitter" emitter; one a null-terminated string value, one an integer value:
copy "cbltypes.cpy".
copy "mfctf.cpy".
01 emitter-name pic x(10) value "myemitter".
01 flags pic x(4) comp-5.
01 prop-integer pic x(4) comp-5.
01 prop-len pic x(4) comp-5.
01 prop-string pic x(100).
...
compute flags = 78-CTF-FLAG-PROP-STRING-VALUE b-or
78-CTF-FLAG-PROP-NULL-TERM
move length of prop-string to prop-len
call "CBL_CTF_EMITTER_PROPERTY_GET" using
by value flags
by reference emitter-name
by reference "prop1 "
by reference prop-len
by reference prop-string
...
compute flags = 78-CTF-FLAG-PROP-INT-VALUE
call "CBL_CTF_EMITTER_PROPERTY_GET" using
by value flags
by reference emitter-name
by reference "prop2 "
by value 0
by reference prop-integer
...