Specifies a value for a component's property.
Restriction: This routine is not currently supported in COBOL for JVM.
Syntax:
call "CBL_CTF_COMP_PROPERTY_SET" using by value flags
by reference component-id
by reference property-name
by reference property-value
returning status-code
Parameters:
|
Using call prototype (see
Key)
|
Picture
|
flags
|
cblt-x4-comp5
|
pic x(4) comp-5
|
component-id
|
pic x(n)
|
pic x(n)
|
property-name
|
pic x(n)
|
pic x(n)
|
property-value
|
pic x(n)
|
pic x(n)
|
status-code
|
See
Library Routines - Key
|
|
On Entry:
-
flags
- Control flags:
- Bit 0
-
Value
|
Meaning
|
0
|
Specify a string value. Use bit 1 to determine the string terminator.
|
1
|
Specify an integer value. Ignore bit 1.
|
- Bit 1
-
Value
|
Meaning
|
0
|
String value is space-terminated.
|
1
|
String value is null-terminated.
|
- Bits 2-28
- Reserved for future use. Must be 0.
- Bit 29
-
Value
|
Meaning
|
0
|
property-name is space-terminated.
|
1
|
property-name is null-terminated.
|
- Bit 30
-
Value
|
Meaning
|
0
|
component-id is space-terminated.
|
1
|
component-id is null-terminated. This is ignored if bit 31 is unset.
|
- Bit 31
-
Value
|
Meaning
|
0
|
component-id is a pic x(4) comp-5 tracer handle returned from a call to CBL_CTF_TRACER_GET if bit 31 of
flags is not set, or a pic x(n) text identifier if bit 31 of
flags is set.
|
1
|
component-id is a pic x(n) text string. The termination character for the string is defined by bit 30.
|
-
component-id
- Component identifier. This is either a pic x(4) comp-5 tracer handle (from CBL_CTF_TRACER_GET) if bit 31 of
flags is not set, or a pic x(n) text identifier if bit 31 of
flags is set.
-
property-name
- Space- or null-terminated (depending on the setting of bit 29) case-insensitive property whose value is to be returned.
-
property-value
- Buffer containing the property value to be set. This is either a pic x(
n) field for a value being specified as a string, or a pic x(4) comp-5 field for a value being set as an integer.
On Exit:
-
status-code
- One of:
- 78-CTF-RET-INVALID-COMP-NAME
- 78-CTF-RET-INVALID-TRACE-HANDLE
- 78-CTF-RET-INVALID-PROP-NAME
- 78-CTF-RET-NOT-ENOUGH-MEMORY
- 78-CTF-RET-SUCCESS
Example:
To acquire a tracer handle to trace "mycomp" component events, and set two "mycomp" property values; one a null-terminated
string value, the other an integer value:
copy "cbltypes.cpy".
copy "mfctf.cpy".
01 component-id pic x(7) value "mycomp ".
01 flags pic x(4) comp-5.
01 prop-integer pic x(4) comp-5.
01 prop-string pic x(100).
01 tracer-handle pic x(4) comp-5.
...
call "CBL_CTF_TRACER_GET" using by value 0
by reference component-id
by reference tracer-handle
...
compute flags = 78-CTF-FLAG-PROP-STRING-VALUE b-or
78-CTF-FLAG-PROP-NAME-NULL-TERM
move "xxxx" & x"00" to prop-string
call "CBL_CTF_COMP_PROPERTY_SET" using by value flags
by reference tracer-handle
by reference "prop1 "
by reference prop-string
...
compute flags = 78-CTF-FLAG-PROP-INT-VALUE
move 100 to prop-integer
call "CBL_CTF_COMP_PROPERTY_SET" using by value flags
by reference tracer-handle
by reference "prop2 "
by reference prop-integer
...
Comments:
Use CBL_CTF_COMP_PROPERTY_SET to set a named property value for the component identified by component-id. If a property with the same name already exists for the component, its value is replaced with the new value. This routine provides equivalent functionality to the mftrace.comp.component-name#property configuration file entry.