OpenESQL

Linking

If you use CHARSET(EBCDIC) when compiling COBOL code that contains SQL host variables that are of the display numeric type defined as XXXXXX, you must link to the oesqlebc library to prevent link errors.

On UNIX/Linux, the symbol oesqleb2 is defined in the shared objects coboesqlebc.so (32-bit) and coboesqlebc64.so (64-bit). To resolve the link error, compile using the -d flag as follows:

cob -x program.cbl -d {oesqleb2@coboesqlebc.so | oesqleb2@coboesqlebc64.so}

Where program.cbl is the name of your COBOL program file.

Embedded SQL Statements

Any EXEC SQL statement that specifies a table or column name containing one or more special characters must have that table or column name enclosed in quotes to prevent a preprocessor error. A special character is an ASCII character with a value greater than 128 or a hexadecimal character with a value greater than x"80".

ODBC

When using Oracle's ODBC driver, array fetches and some scrolling fetches might produce inconsistent behavior if you change the array size between fetches. To overcome this, build your application with SQL(NORESULTARRAY). When this is set, OpenESQL performs single row fetches under the covers, bypassing this limitation.

OpenESQL ODBC Native Runtime

OpenESQL applications are optimized for performance by default, with OpenESQL now implicitly setting the BEHAVIOR compiler directive to OPTIMIZED; with previous products, the BEHAVIOR compiler directive was implicitly set to UNOPTIMIZED. This change can impact program behavior as follows:

  • Programs that include the SET SCROLLOPTION or SET CONCURRENCY EXEC SQL statements fail to compile. For affected programs, do one of the following:
    • Before compiling, set the BEHAVIOR compiler directive to UNOPTIMIZED. While this is the simplest solution, we do not recommended it due to the possibility of degraded performance.
    • Remove all SET SCROLLOPTION and SET CONCURRENCY statements and, if necessary, modify the DECLARE CURSOR statement to include appropriate parameters to yield the same behavior. For example, to elicit the same behavior as the SET SCROLLOPTION statement, use the following DECLARE CURSOR statement:
      EXEC SQL DECLARE cursorname SCROLL LOCK CURSOR FOR…

      By default, cursors are forward and read only. If this is the desired behavior, you can safely remove the SET statements with no further action required. However, we recommend as a matter of good practice to always include FOR READ ONLY or FOR UPDATE in cursor declarations to ensure that the default behavior is always explicit. We recommended this solution.

  • The OPTIMIZED setting does not make ambiguous cursors updateable. Therefore, applications that expect cursors to be updateable, according to the default ANSI standards for Embedded SQL, are affected. In this case, we recommend that you set the BEHAVIOR compiler directive option to ANSI.
  • The OPTIMIZED setting does not assume scrollable cursors. Therefore, applications that expect cursors to be scrollable are affected. In these cases, we recommend that you modify your DECLARE CURSOR statements to compensate, as specified above.
Important: If you do not want to take advantage of the performance gains provided by this change in implicit behavior, use the OpenESQL Configuration Utility to change the implicit value of the BEHAVIOR compiler directive back to UNOPTIMIZED. For details, see OpenESQL Embedded SQL Cursor Behavior and Performance.

PostgreSQL Recommendations

  • PostgreSQL does not accept NULL date, time, or timestamp values from PIC X host variables. You must either use CAST(:hostvar as TIMESTAMP) in the SQL or use SQL TYPE TIMESTAMP in the application.
  • PostgreSQL supports embedded NULL characters in binary columns only; it does not support embedded NULL characters in character columns.
  • When using PostgreSQL with ODBC and a negative SQL code is returned to a calling application, PostgreSQL aborts transactions implicitly unless you change the default behavior of the ODBC driver. In addition, PostgreSQL does not support the ODBC API call SQLSetPos, which impedes the performance of updateable cursors.

    To work around these shortcomings, consider modifying the psqlODBC driver Configuration Options. To do this:

    1. Invoke the PostgreSQL ANSI or UNICODE ODBC Driver (psqlODBC) Setup dialog box.
    2. Click Datasource.
    3. On Advanced Options page 1, check Use Declare/Fetch.
    4. Click Page 2.
    5. On Advanced Options page 2, set the Level of rollback on errors option to Statement, and uncheck Updatable Cursors.

Programming

  • The program name for both calling and called OpenESQL programs must be unique within the first 30 characters.