No TrueLog is generated
If you do not have a TrueLog result file after test execution make sure that:
- The
Silk4NET project is executed in the same
Visual Studio version as the version in which the project was created. For example, you can only execute a
Silk4NET project which is created in
Visual Studio 2012 within a
Visual Studio 2012 environment. This limitation also applies when you execute the project through the command line or through Team Foundation
Server.
- The test class contains the
SilkTestClass attribute.
- You have write access to the location where the TrueLog file is created.
Silk4NET displays the message "Unit Test Adapter threw exception…
"
If you get the error message
Unit Test Adapter threw exception…
during replay, ensure that the
Silk4NET project is executed in the same
Visual Studio version as the version in which the project was created. For example, you can only execute a
Silk4NET project which is created in
Visual Studio 2012 within a
Visual Studio 2012 environment. This limitation also applies when you execute the project through the command line or through Team Foundation
Server.
How to migrate
Silk4NET projects created in a prior version of
Visual Studio to a later version of
Visual Studio:
- Open the solution in the prior version of
Visual Studio.
- Change the target framework of your
Silk4NET projects to the appropriate version of the .NET Framework. For example, to migrate the projects from
Visual Studio 2010 to
Visual Studio 2012, set the target framework to .NET Framework 4.5.
- Remove the reference to the
UnitTestingExtension of the prior version of
Visual Studio from your
Silk4NET projects. For example, if the prior version is
Visual Studio 2010, remove the reference to
SilkTest.Ntf.VisualStudio2010.UnitTestingExtension from your
Silk4NET projects.
- Add the reference to the later version of
Visual Studio to your
Silk4NET projects. For example, to migrate the projects to
Visual Studio 2012, add the reference
SilkTest.Ntf.VisualStudio2012.UnitTestingExtension to your
Silk4NET projects.
When you are using object maps, existing locators that do not start with a slash will no longer work
Locators that include only a class name and that do not start with a slash, for example
PushButton, will no longer work if object maps exist. This issue might result in breaking existing scripts that were created in a
Silk Test version prior to
Silk Test 14.0. For the previous example the script will fail with the following error:
Identifier 'PushButton' was not found in the Object Map.
More complex locators that include more than a class name, for example
PushButton[@caption=OK] will continue to work, even if object maps exist.
To fix this issue, add a
// to the start of any such locator. For example, if the locator
PushButton in the following code does no longer work:
PushButton button = mainWindow.find("PushButton");
Change the code to:
PushButton button = mainWindow.find("//PushButton");
Why do I get the message "Could not load 64bit JVM..." when replaying a keyword-driven test?
When replaying a keyword-driven test with
Silk4NET 19.5 or later, you might get the following error message:
Could not load 64bit JVM. The test runner is using 32bit. For additional information, see Known Issues > Silk4NET in the help.
To solve this issue, do one of the following: