SnmpGetValue Function

Action

This function returns for a provided OID the actual value.

Include file

Snmp.bdh

Syntax

SnmpGetValue( in  hSnmp      : number,
              in  sOid       : string,
              out sValue     : string,
              in  nValueSize : number optional ): boolean;

Return value

  • true if successful

  • false otherwise

Parameter Description
hSnmp Handle from SnmpOpenConnection().
sOid OID in dotted notation.
sValue Returns actual value.
nValueSize Size of the buffer sValue (optional).

Example

  benchmark Collect 

use "pdce.bdh"  
use "snmp.bdh" 

const
  MEASURE_COMMUNITY   := "public";
  MEASURE_VERSION     := "V1";
  MEASURE_NAME        := "System/Services";
  MEASURE_MACHINE     := "machineName:161";
  MEASURE_MIB         := "RFC1213-MIB";
  MEASURE_OID_NAME    := "system.sysServices";

var
  nInterval         : number;
  hClient1          : number;
  hMeasure1         : number;
  sKey1             : string(1024);

dcluser
user
  Collect
transactions
  NoTRT_TStartup : begin;
  NoTRT_TCollect : 5;
  NoTRT_TEnd     : end;                              

dclfunc
  function PdceGetSnmpKey(sKey       : string;
                          sMachine   : string;
                          sMib       : string;
                          sCommunity : string;
                          sVersion   : string;
                          sOidName   : string;
                          nInstance  : number optional) : boolean        

  var
    sMibOid        : string(1024);
    sInstanceOid   : string(1024);
    sValue         : string(1024);
    sOid           : string(1024);
    hSnmp          : number;         // SNMP connection handle
  begin

    hSnmp := SnmpOpenConnection(sMachine, sMib, sCommunity, sVersion);

    if ( hSnmp <> 0 ) then
      SnmpGetMibOid(hSnmp, sOidName, sMibOid);                   

      Print("OID for " + sOidName + " : " + sMibOid);

      SnmpGetFirstInstanceOid(hSnmp, sMibOid, sInstanceOid);
      while SnmpGetNextInstanceOid(hSnmp, sInstanceOid) do
        sOid := sMibOid + "." + sInstanceOid;
      end;

      Print("OID with first instance: " + sOid);

      if SnmpGetValue(hSnmp, sOid, sValue) then
        Print("Value: " + sValue);
      end;

      sKey :=  "SNMP:" + sOid +"@" + MEASURE_MACHINE + "?" + SNMP_COMMUNITY_PUBLIC + "&" + SNMP_VERSION_1;
      PdceGetSnmpKey := true;

      SnmpCloseConnection( hSnmp )
    end;           
             
    PdceGetSnmpKey := false;                  

  end PdceGetSnmpKey;
                                         
dcltrans
  transaction NoTRT_TStartup
  begin

      PdceGetSnmpKey( sKey1, MEASURE_Machine, MEASURE_MIB, MEASURE_COMMUNITY, MEASURE_VERSION, MEASURE_OID_NAME);

      PdceStartUp();
      PdceRegisterClient(hClient1, nInterval);
      PdceAddMeasure(hClient1, MEASURE_NAME, sKey1, hMeasure1);

      Wait(float(2*nInterval));
  end NoTRT_TStartup;   

transaction NoTRT_TCollect      
var
    fLastValue, fSum, fMin, fMax, fAvg, fStDev : float;
    uTimeStamp, uStatus  : number;
  begin
    PdceGetMeasureValue(hMeasure1, MEASURE_NAME);
    if (GetWorkloadModel() <> WORKLOAD_MONITORING) then
      Wait(float(nInterval));
    end;

    if PdceMeasureQueryValue(hMeasure1, fLastValue, fSum, fMin, fMax, fAvg, fStDev, uTimeStamp, uStatus) then
      Print("Query value: " + String(fLastValue) );
    end;
  end NoTRT_TCollect;

  transaction NoTRT_TEnd
  begin
    PdceMeasureUnSubscribe(hMeasure1);
    PdceClientUnRegister(hClient1);
    PdceCleanUp();