These issues should be understood in the context of eDirectory non-replica servers. These issues can occur on OES or eDirectory. For more information, see documentation on the OES 2018 SP3 Online documentation site.
Unable to start/stop the Print Manager/Driver Store from iManager
SLP-DA (Directory Agent)
Multicast SLP
There are two possible problems for a non-replica OES server in SLP-DA mode:
The non-replica OES server is not able to reach the DA server.
The replica OES server is not able to reach the DA server.
There is one possible cause for this problem for a non-replica OES server in Multicast SLP mode:
The firewall is on, so multicast communication is not possible.
If the message indicates Replica server is not able to reach the DA server, ensure the DA server is within the multicast range of the replica server. If it is not within the multicast range, provide the IP address of the DA server in the SLP configuration file of the replica server.
For details on SLP configuration and setting up the DA server, see “Configuration Parameters” of the NetIQ eDirectory 8.8 Administration Guide.
For the Multicast SLP configuration, turn the firewall off.