Configure Connection Settings Dialog Box for VT
How do I get to this dialog box?
-
Open a session document.
-
Open the Settings window.
The steps depend on your user interface mode.
User Interface Mode Steps Ribbon or InfoConnect Browser With a session open in InfoConnect, from the Quick Access Toolbar, click . TouchUx Tap the Gear icon and then select Document Settings. -
Under Host Connection, click Configure Connection Settings.
From this dialog box, you can specify the settings for a VT connection.
Connection Method
Setting | Description |
---|---|
Network | Configure a host connection through a network. |
Serial Port | Configure a host connection through a serial port on your PC. |
Modem | Configure a host connection through a modem. The modem must first be configured in Windows. |
Network
These options are available only when you have selected Network under Connection Method.
Network Connection Type
Setting | Description |
---|---|
Telnet | Select to use your PC as a virtual terminal over a TCP/IP connection. When Telnet is the selected protocol, you can configure secure connections using SSL/TLS. |
Secure Shell | Select for secure, encrypted communications between a trusted host and your PC over an insecure network. When you select Secure Shell, all connections between your PC and the remote host(s) are encrypted, protecting the data sent between these machines. |
Rlogin | Select to use your PC as a virtual terminal over a TCP/IP connection. |
Connection Options
Setting | Description |
---|---|
Host name/IP address | Identify the host to which you will connect. Type the host name, alias, or numeric IP address. |
Note: Both IPv4 addresses (in the form 127.0.0.1) and IPv6 addresses (in the form 2001:0db8:3c4d:0015:0000:0000:abcd:ef12) are accepted. | |
User name | Type a name that identifies you or your PC to the host. This option is enabled only for Secure Shell or Rlogin connections. |
SSH configuration scheme | Type a descriptive name to label these connection settings, making them available for use with other Secure Shell sessions. If you leave this field blank, and make changes to any connection settings, InfoConnect saves the configuration scheme using the value from the Host name/IP address field. |
Handle SSH User authentication in terminal window | For Secure Shell connections, display user name and password prompts in the terminal window instead of in a dialog box. |
Security | Secure data communications with Secure Shell, SOCKS, or SSL/TLS. |
More Settings | Configure additional settings. |
Serial Port
These options are available only when you have selected Serial Port under Connection Method.
Setting | Description |
---|---|
Serial port to use | InfoConnect detects available serial ports on your PC and displays them here. |
Parity | Set the parity for data transmission to and from the serial device on this port. This setting determines whether a parity bit is generated for each character transmitted. Parity is used to detect errors in data transmission; the number preceding the slash indicates the number of data bits sent. |
To use the multinational character set or 8-bit controls, Parity must be set to one of the values that offers 8-bit controls. If your communications link generates parity, and you set Parity to 8/None, multinational characters appear on your screen. In this case, set Parity to either 8/Even or 8/Odd. | |
Baud | Set the rate at which InfoConnect transmits and receives data through the selected serial port. The baud rate setting must match the baud rate of your direct connection. |
More Settings | Configure additional settings. |
Modem
These options are available only when you have selected Modem under Connection Method.
Setting | Description |
---|---|
Modem to use | InfoConnect detects modems configured on your PC and displays them here. |
Phone number | Type the phone number you want the modem to dial when connecting. The number must adhere to the rules of your modem. |
Use country code and city code | Select this option if you want to specify a country code and city code (or area code) for the number you are dialing. Clear this option if you do not want to use the Country code, City code, and Current location options. |
Country code | Type the country code for the country you are calling. |
City code | Type the city code or area code for the location you are calling. |
Current location | Select the previously defined location from which you are calling. These locations are defined from the Dialing Properties dialog box. |
Dialing Properties | Add, modify, or remove a location from the Current location list. |
More Settings | Configure additional settings. |
Connection Options
Setting | Description |
---|---|
Automatically connect to the host | Select to establish a host connection as soon as the associated session document is opened. |
Allow exit while connected | Select to allow closing the workspace when a session is connected to a host. |
When connection is terminated | Specify options for reconnecting after any disconnection that is not initiated from InfoConnect. |
Reconnect automatically specifies to attempt to reestablish the connection. | |
Prompt for reconnection specifies to prompt whether to attempt to reestablish the connection. (When No is selected, the session is left open and disconnected.) | |
Leave disconnected specifies to leave the session disconnected with the session open. | |
Close session automatically specifies to close the session. |
More information