CASTS1000 - CASTS1019
CASTS1000I ES TRC service process (PID:process-id) recovery initiated
The ES TRC server process has been restarted after a failure and the new process is recovering pending requests to the previous server process (PID:
process-id
).
CASTS1001I ES TRC Service Process restart in progress
The ES TRC Service process has been restarted and recovery operations are in progress.
CASTS1002I ES TRC Service Process initialization complete
The ES TRC Service Process has completed initialization.
CASTS1003I ES TRC Service Process termination started
The ES TRC Service Process is terminating.
CASTS1004S ES TRC Service Process registration failed, reason = reason-code
The ES TRC Service Process failed registration.
CASTS1005I ES TRC Service Process termination complete
The ES TRC Service Process has terminated.
CASTS1006I trc-control-message
The ES TRC Service Process issued a message.
CASTS1007I ES TRC Service Process initialization started
The server ES TRC Service Process initialization has started.
CASTS1008S ES TRC Service Process is not running in multi-threaded mode
The ES TRC Service Process has not started with the required underlying thread support.
CASTS1009W TS queue queue name inconsistent end at location location; should be value expected.
The ES TRC process has encountered a problem with temporary storage queue
queue name
.
CASTS1010W TS queue queue name invalid chain start at location location.
The ES TRC process has encountered a problem with temporary storage queue
queue name
.
CASTS1011W TS queue queue name invalid chain next reference next pointer from block block.
The ES TRC process has encountered a problem with temporary storage queue
queue name
.
CASTS1012E trc-control-error-message
The ES TRC Service Process issued an error message.
CASTS1013W ES TRC has temporarily switched HSF off due to max queued work limit (Number of trace tables that can be held) being reached
The spill thread in TRC has reached the maximum number of queued trace tables.
CASTS1014I ES TRC has re-enabled HSF processing because the queued work has been processed
The spill thread in TRC has processed all queued trace tables.
CASTS1018W TS queue queue name invalid segment referenced next pointer from block block.
The ES TRC process has encountered a problem with temporary storage queue
queue name
.
CASTS1019I ES support for CICS TRANCLASS and transaction priority is enabled
CICS TRANCLASS and priority is enabled for Enterprise Server.
Parent topic:
CASTS - TSC Service Process Error Messages