CASAM3020 - CASAM3039
CASAM3020E ES Monitoring and Management detected non-zero value for "Registry key\Registry value name". M & M disabled.
Event manager has detected that performance monitoring has been disabled.
CASAM3021W ES Monitoring and Management unable to get value for "Registry key\Registry value name": RC=Return code for WIN API call "RegQueryValueExA".
Event manager retrieved an unexpected return code when querying the performance registry key value.
CASAM3022W ES Monitoring and Management detected incorrect value for "Registry key\Registry value name": Performance monitoring load module name.
Event manager retrieved an unexpected value when querying the performance registry key value.
CASAM3023E Error accessing file casglm.lck "Return code".
While trying to access the file casglm.lck an error occurred.
CASAM3024E Unable to map shared memory for performance monitoring. Monitoring and Management support disabled. Error: "Return code"
Event Manager is unable to map shared memory for performance monitoring.
CASAM3025I Region detected a timezone/daylight savings time change and automatically reset the time
The system detected that the active timezone changed.
CASAM3026W Region detected a timezone/daylight savings time change - time needs to be reset
The system detected that the active timezone changed.
CASAM3027I Region timezone reset by user (Logged on user) from transaction (Active transaction) at terminal (Active terminal)
The active timezone was reset under programmatic control.
CASAM3028E Unexpected failure renaming current aux trace file to filename for new aux file renamed, reason = File status RC1,File status RC2
ES failed to rename the current aux file The COBOL file status after failure is
File status RC1
,
File status RC2
.
CASAM3029I Aux trace switching notification exit enabled (exit-program-name)
Castrc loaded the user-defined exit.
CASAM3030E ES Monitoring and Management failed to initialise counters. RC=Return code for WIN API call "CounterInitialize".
Castrc retrieved an unexpected return code when initialising the V2 performance counters.
CASAM3031E ES Monitoring and Management failed to create a counterset instance. RC=Return code for WIN API call "PerfCreateInstance".
Castrc retrieved an unexpected return code when creating an instance of the V2 performance counters.
CASAM3032E ES Monitoring and Management failed to load the counter values. RC=Return code for WIN API call "PerfSetCounterRefValue".
Castrc retrieved an unexpected return code when finding the value associated with a V2 performance counter.
Parent topic: