These environment variables relate to configuring the input and output and the display.
Syntax
Windows:
set CCITCP2=hostname
UNIX:
CCITCP2=hostname
export CCITCP2
Parameters
hostname is the TCP hostname or dotted decimal IP address of the machine running the CCITCP2 daemon you wish to contact from that session.
Comments
The environment variable value will always take precedence over any value set using the Configuration Utility. To restore a process to using the value set by the Configuration Utility simply set the environment variable to an empty string, such as
set CCITCP2=
Alternatively, if this environment variable is set system-wide (by creating a system variable in the system environment settings, or by using a CONFIG.SYS file) then this value will always take precedence over any value set using the Configuration Utility.
Syntax
Windows:
set CCITCP2_PORT=port
UNIX:
CCITCP2_PORT=port
export CCITCP2_PORT
You can specify the type of information that will be recorded by CCI tracing. To do this, configure the CCITRACE environment variable as follows:
CCITRACE=options
where any, or all, of the following options can be specified with a preceding / or -:
The ctf.cfg and the CCI.INI file ([ccitrace_base] section) can also be used to control trace options, but any values specified by the CCITRACE environment variable will take precedence.
Specifies the directory path that Animator is to search for the session (.aif) file for the program being animated, if it is not found in the same directory as the information (.idy) file. Animator can update the session file to record information held between sessions. The .aif file contains details of breakpoints and monitors.
Syntax
COBAIF=pathname export COBAIF
Parameters
Comments
If the .aif file is not found in the directory specified, a search is made of the directories specified by the COBIDY environment variable. If the file is still not found, the current directory is searched.
If an .aif file does not exist, Animator creates it as follows:
Specifies the basename of the Animator session file (.aif ) for the program being animated. The .aif file contains details of breakpoints and monitors.
Syntax
COBAIFNAME=basename export COBAIFNAME
Parameters
Comments
You need to specify this environment variable if you are starting Animator using COBSW=+A and you want to save breakpoints for subsequent animation sessions. You can also specify it if you are starting Animator using the command anim; in this case the basename you specify overrides the application name as the basename of the .aif file.
Specifies non-standard behavior for HIGHLIGHT and LOWLIGHT clauses used with ACCEPT and DISPLAY statements. It provides compatibility with earlier COBOL products. You should avoid using it wherever possible as support might be discontinued at some future date.
Syntax
COBATTR=n export COBATTR
Parameters
n A value in the range 0 through 7. It can be one of the following values, or a cumulative value; for example, specifying a value of 6 would result in the behavior described for values 4 and 2.
Provides standard, default behavior.
When a COBOL program displays text subject to a HIGHLIGHT or LOWLIGHT clause, the run-time system uses respectively the bold or dim mode specified in the terminfo entry for the terminal. If the bold or dim mode is not specified, then the HIGHLIGHT or LOWLIGHT clause respectively has no effect.
When a COBOL program displays text subject to a HIGHLIGHT clause, the run-time system uses the bold mode. The run-time system uses the default mode for normal text. Specifying dim mode in the terminfo entry for the terminal has no affect. The LOWLIGHT clause has no effect.
High and low intensity space characters are not assumed to be the same as normal mode space characters.
As for 1 and 2 above
Provides compatibility with default behavior of products before COBOL version 3.2.
When a COBOL program displays text subject to a HIGHLIGHT clause, the effect depends on whether the dim mode is specified in the terminfo entry for the terminal. If dim mode is specified, then the run-time system uses the default mode for highlighted text and the dim mode for normal text. If the dim mode is not specified, then the run-time system uses the bold mode for highlighted text and default mode for normal text. The LOWLIGHT clause has no effect, giving the same appearance as normal text.
Example
COBATTR=1 export COBATTR
Specifies a run-time configuration file that tailors the run-time configurable options in some way.
Syntax
Windows:
SET COBCONFIG=pathname
UNIX:
COBCONFIG=pathname
export COBCONFIG
Parameters
Comments
If $COBCONFIG is not set then the file $COBDIR/etc/cobconfig is searched for instead.
Example
UNIX:
COBCONFIG=/home/mydir/cobconfig
export COBCONFIG
Windows:
SET COBCONFIG=/home/mydir/cobconfig
Values
COBDIR=path-name
On Windows platforms, the Micro Focus COBOL system is normally installed in the default COBOL system directory and so does not require COBDIR to be set. COBDIR only needs to be set when your COBOL system has been installed in a different directory such as when more than one version of the COBOL system is available at the same time.
Windows platforms:
This example causes the compiler to search the directory C:\products\cobse20 for the Micro Focus COBOL system software:
COBDIR=C:\products\cobse20
UNIX platforms:
This example causes the compiler to search the directory /home/products/cobse20 for the Micro Focus COBOL system software.
COBDIR=/home/products/cobse20
Specifies the maximum elapsed time, in tenths of a second, for the connected terminal to transmit any valid escape sequence to the run-time system.
When a terminal key is depressed, the terminal might send in response a single character or a group of characters to the run-time system. Typically, such a group of characters starts with an escape character and the group of characters is known as an escape sequence. A terminal might send an escape sequence for one depression of a function key. It might also send the same sequence of characters for a depression of the Escape key followed by the depression of one or more alphabetic or numeric data keys. The only difference apparent to the run-time system is the interval between the arrival of each character; the user cannot type as fast as the escape sequence is generated by the terminal.
If a terminal is connected over a network that sends the characters to the run-time system in discrete packets, then the network can alter the intervals between each character arriving at the run-time system. COBKEYTIMEOUT is available to help compensate for typical network delays so the run-time system identifies escape sequences correctly.
Syntax
Windows:
SET COBKEYTIMEOUT=n
UNIX:
COBKEYTIMEOUT=n
export COBKEYTIMEOUT
Parameters
n A number in the range 1 through 126 that represents the maximum elapsed time required for a terminal to transmit any valid escape sequence to the run-time system over the line or network connection. On encountering a lone Escape character, the run-time system waits n tenths of a second before assuming that the character does not introduce an escape sequence. The run-time system calculates an appropriate default value for n from the baud rate of the terminal.
Example 1:
COBLPFORM 1:3:5:7:9:11:13:15:17:19:21:23
In this example C01 equals 1, C02 equals 3, and so on.
Example 2:
COBLPFORM :3::5: :9
In this example, C01 equals 3, C02 equals 5, C03 equals 1, and C04 equals 9. You can specify only a single line number for each channel.
In example 2 above, channels C05 - C12 are undefined. If a print statement specifies channel C05 - C12, the line is printed at line 1. In addition, in the example shown, C03 equals 1 because its value is a space and therefore undefined.
Any WRITE BEFORE/AFTER PAGE statements cause positioning to be at line 1. Each line advance increases the line number by one. A request to skip to a line number less than or equal to the current line causes a new page to begin. The appropriate number of line feeds are then generated.
This variable is used to specify the size of the main stack.
Syntax
Windows:
SET COBMAINSTACK=n
UNIX:
COBMAINSTACK=n
export COBMAINSTACK
Parameters
n - The size, in bytes, of the stack.
The main stack size defaults to three times the size of a threaded stack. The size of a threaded stack is either specified when the stack is created (using CBL_THREAD_CREATE), or it defaults to 160KB for a 32-bit application or 320KB for a 64-bit application.
You might need to set COBMAINSTACK in any of the following circumstances:
Syntax
COBMODE=mode; export COBMODE
Parameters
mode = 32 or 64.
Example
COBMODE=32; export COBMODE
Syntax
COBOPT="[set environment-variable=value] [options] ... [cobextn: .ext [.ext] ... ]" export COBOPT
or
COBOPT=[pathname/]filename export COBOPT
If a line does not begin with one of the identifiers set or cobextn: then it is taken as an options line.
Comments
COBOPT can either contain options that supplement or override the system default options defined in $COBDIR/etc/cobopt, or it can specify the path of a file that contains such options. The options can extend over more than one line and each line must have the same format as described for the file $COBDIR/etc/cobopt in the chapter COBOL System Interface (cob).
Examples
COBOPT="CANS85 set COBCPY=$COBDIR/srclib/:$HOME/mylib:" export COBOPT
This enables ANSI 85 standard COBOL syntax and sets COBCPY to the specified list of paths.
COBOPT=temp/options
Specifies that cob options are contained in the file options in the directory temp.
Specifies the directory or directories that the run-time system is to search for dynamically loadable .int and .gnt files, or callable shared objects.
Syntax
Windows:
SET COBPATH=pathname[:pathname]...
UNIX:
COBPATH=pathname[:pathname]...
export COBPATH
Parameters
pathname A list of search directories, each item separated by a semicolon (Windows) or colon (UNIX), that the run-time system is to search for a dynamically loadable program (.int, .gnt or callable shared object) file. When more than one pathname is specified, a null pathname represents the current working directory.
Example
Windows:
SET COBPATH=u:/home/mydir/srclib:otherlib
UNIX:
COBPATH=u:/home/mydir/srclib:otherlib
export COBPATH
Specifies the name of a print spooler that is to receive, via its standard input stream (stdin), output from any DISPLAY UPON PRINTER statement.
Syntax
Windows:
SET COBPRINTER=command-line
UNIX:
COBPRINTER=command-line
export COBPRINTER
Parameters
Comments
Each DISPLAY UPON PRINTER statement executed by your COBOL program causes a new invocation of command-line. Each invocation receives the data referenced in the DISPLAY statement, and is followed by a system end-of-file condition.
Example
Windows:
SET COBPRINTER="myspooler -a $TMPDIR\spoolfile"
UNIX:
COBPRINTER="myspooler -a $TMPDIR/spoolfile"
export COBPRINTER
Specifies the UNIX Session Recorder functions to perform.
Syntax
COBSES={option[filename]}... export COBSES
option can be one or more of the following:
These flags are all case sensitive. Also, you cannot combine the -r flag with either -f or -p.
Syntax
Windows:
SET COBSW=[+/-}s...
UNIX:
COBSW=[+/-}s...
export COBSW
A list of the run-time switches to set or unset.
Example
Windows:
SET COBSW=+0+D
UNIX:
COBSW=+0+D
export COBSW
This enables run-time switch 0 and the ANSI COBOL debug switch.
COBTERMINFO=pathname[:pathname]... export COBTERMINFO
Parameters
pathname A list of search directories, each item separated by a colon, that identify a terminfo database containing terminal settings tailored for COBOL applications. A null pathname represents the current working directory.
Comments
The COBOL system takes the value of the standard UNIX environment variable TERM as the name of the terminal in use. It uses this to search for the appropriate terminal information in a terminfo database. The run-time system first searches the databases identified in COBTERMINFO and then, if the terminal information is not found it searches the database identified in the standard UNIX environment variable TERMINFO.
If COBTERMINFO is not set, the run-time system acts as if it had been set to $COBDIR/terminfo.
Micro Focus recommend that the first directory listed in COBTERMINFO is $COBDIR/terminfo so that the terminfo database supplied with this COBOL system is found first. For commonly used terminals this terminfo contains settings that are fuller and more appropriate to COBOL than those normally available in the UNIX system terminfo database. When debugging using Animator, COBTERMINFO must be set to $COBDIR/terminfo.
COBTERMINFO can also be used to identify a terminfo database that is portable between UNIX systems. Such a database conforms to the standard UNIX database format but does not include any supplementary, UNIX implementation-dependent terminal information. Many UNIX system terminfo databases are not portable because they include such supplementary information. The COBOL system ignores any such nonportable details.
Example
COBTERMINFO=$COBDIR/terminfo:/home/mydir/terms export COBTERMINFO
Specifies the column width of the terminal screen or window, overriding the specified terminal default.
Syntax
COLUMNS=n export COLUMNS
Parameters
n The width of the terminal screen or window, in column positions.
Comments
The default, when COLUMNS is unset or null, is to use the cols value defined in the specified terminal's terminfo entry, or the current width of the terminal window if you are using an X terminal. The terminal type is specified using the standard UNIX environment variable, TERM.
On non-windowing environments, where the terminal screen area cannot be resized, the COLUMNS values does not need to be set. Terminals that can switch into a wide mode (usually from 80 through 132 columns) have a terminal name ending in "w" and these are automatically supported, without the need to set COLUMNS.
In windowing environments, where the size of windows can be changed, the initial size of the window is used in preference to the cols value in terminfo. When the window is resized, the new size is reread. If the new size is greater than the initial size then the extra columns might not be used.
If you want to use the full width of the window you might need to set COLUMNS to the current column width of the window on some platforms.
Using COLUMNS values that do not correspond to the actual width of the window produces unexpected results.
Example
COLUMNS=100 export COLUMNS
UNIX:
ES_CAS_API=value
export ES_CAS_API
Windows:
SET ES_CAS_API=value
The utility will attempt to log messages.
ES_CONSOLE_LOG=port export ES_CONSOLE_LOG
Can be any combination of the following:
UNIX:
ES_ESMAC_DISP_MAX_OVERRIDE=value
export ES_ESMAC_DISP_MAX_OVERRIDE
Windows:
ES_ESMAC_DISP_MAX_OVERRIDE=value
UNIX:
ES_JES_SPOOL_ORDER=value
export ES_JES_SPOOL_ORDER
Windows:
ES_JES_SPOOL_ORDER=value
1 - Displays the list in descending order by JOBID. Any other value displays it in ascending order.
UNIX:
ES_LEGACY_ECI=value
export ES_LEGACY_ECI
Windows:
ES_LEGACY_ECI=value
UNIX:
ES_MAX_CATALOG_LINES=number
export ES_MAX_CATALOG_LINES
Windows:
ES_MAX_CATALOG_LINES=number
UNIX:
ES_OTMA_TIMEOUT=seconds
export ES_OTMA_TIMEOUT
Windows:
SET ES_OTMA_TIMEOUT=seconds
Syntax
UNIX:
ES_SEP_DORMANT_TIME=seconds
export ES_SEP_DORMANT_TIME
Windows:
ES_SEP_DORMANT_TIME=seconds
Values
Default
Transient SEPs are terminated after 2 seconds of inactivity.
Syntax
UNIX:
ES_SERVER=name
export ES_SERVER
Windows:
ES_SERVER=name
Values
Default
ESDEMO/ESDEMO64
ES_SYSOUT_HOLD={Y|N}
Default: | None |
Syntax
UNIX:
ES_TN2370_FORCE_ALT=value
export ES_TN2370_FORCE_ALT
Windows:
SET ES_TN2370_FORCE_ALT=value
Values
Default
The default screen size is used.
Syntax
UNIX:
ES_TN3270_MODEL_LOG=value
export ES_TN3270_MODEL_LOG
Windows:
SET ES_TN3270_MODEL_LOG=value
Values
Default
Model names are not logged.
Syntax
UNIX:
ES_USR_DFLT_CICS=user
export ES_USR_DFLT_CICS
Windows:
SET ES_USR_DFLT_CICS=user
Values
Default
CICSUSER
Syntax
UNIX:
ES_USR_DFLT_ESMAC=user
export ES_USR_DFLT_ESMAC
Windows:
SET ES_USR_DFLT_ESMAC=user
Values
Default
mfuser
Syntax
UNIX:
ES_USR_DFLT_JES=user
export ES_USR_DFLT_JES
Windows:
SET ES_USR_DFLT_JES=user
Values
Default
JESUSER
Syntax
UNIX:
ES_ESM_DISABLE_DFLTUSER_ESMAC=value
export ES_ESM_DISABLE_DFLTUSER_ESMAC
Windows:
ES_ESM_DISABLE_DFLTUSER_ESMAC=value
Values
Default
Default ESMAC user is not disabled.
Syntax
LANG=language[_territory[.codepage]] export LANG
Example
LANG=fr_FR export LANG
Syntax
LINES=n export LINES
Parameters
n The depth of the terminal screen or window, in lines.
Comments
The default, when LINES is unset or null, is to use the lines value as defined in the specified terminal's terminfo entry, or the current depth of the terminal window if you are using X windows. The terminal type is specified via the standard UNIX environment variable, TERM.
On non-windowing environments, where the terminal screen area cannot be resized, the LINES values does not need to be set.
In windowing environments, where the size of windows can be changed, the initial size of the window is used in preference to the lines value in terminfo. When the window is resized, the new size is reread. If the new size is greater than the initial size then the extra lines might not be used.
If you want to use the full depth of the window you might need to set LINES to the current depth of the window on some platforms.
Using LINES values that do not correspond to the actual depth of the window produces unexpected results.
Example
LINES=50 export LINES
Specifies the directory or directories for the UNIX system, cob command, and the run-time system to search for shared libraries and callable shared objects. If you have installed the product to a directory other than the default one, you must set this variable to include $COBDIR/lib on all platforms except AIX (which uses LIBPATH). It should also include any directories that contain callable shared objects used by your application. If you have installed the product in the default directory (/opt/microfocus/EnterpriseDeveloper), you do not need to set this variable.
Syntax
LD_LIBRARY_PATH=pathname[:pathname]... export LD_LIBRARY_PATH
pathname A path or a list of paths, each separated by a colon (:).
Comments
The list of directories must include $COBDIR/lib. The COBDIR environment variable is described earlier.
This environment variable is a system environment variable; see your UNIX documentation for more information.
Example
LD_LIBRARY_PATH=$COBDIR/lib:/home/mydir/myapp:$LD_LIBRARY_PATH export LD_LIBRARY_PATH
Syntax
LIBPATH=pathname[:pathname]... export LIBPATH
Parameters
pathname A directory to search for shared libraries.
Example
LIBPATH=$COBDIR/lib:/lib:/usr/lib
Syntax
Windows:
SET MAINFRAME_FLOATING_POINT=fpstatus
UNIX:
MAINFRAME_FLOATING_POINT=fpstatus
export MAINFRAME_FLOATING_POINT
Parameters
fpstatus Which format to use for floating point data items. This must be one of:
Setting MAINFRAME_FLOATING_POINT to anything other than true has the same effect as setting it to false.
The setting of this environment variable can be overridden by the NATIVE-FLOATING-POINT directive.
Syntax
Windows:
SET MF_SPOOL_ARCHIVE_LOC=file-location
UNIX:
MF_SPOOL_ARCHIVE_LOC=file-location
export MF_SPOOL_ARCHIVE_LOC
Values
file-location The file location.
MF_USESCA7={ON|OFF}
Default: | MF_USESCA7=ON |
Country Code (MFCODESET) |
EBCDIC CCSIDs | Language |
---|---|---|
AUTOMATIC
AUTO |
Operating system default - sets country code based on CBL_GET_OS_INFO
This setting is only applicable on Windows platforms. |
|
DEFAULT | Set to 0437 (US English) on Windows, or 0081 (Japanese Katakana Extended) on Japanese Windows. Set to 0437 (US English) on UNIX. | |
0031 | 37, 1140 | Dutch |
0033 | 297, 1147 | French |
0034 | 284, 1145 | Spanish |
0039 | 280, 1144 | Italian |
0043 | 273, 1141 | German (Austrian) |
0044 | 285, 1146 | UK English |
0045 | 277, 1142 | Danish |
0046 | 278, 1143 | Swedish |
0047 | 277, 1142 | Norwegian |
0049 | 273, 1141 | German |
0066 | 838 | Thai Extended |
0081† | 930 (290, 300) | * Japanese Katakana Extended |
0082 | 933 (833, 834) | *Korean |
0086 | 13676 (836, 837) | *Simplified Chinese |
0351 | 37, 1140 | Portuguese |
0358 | 278, 1143 | Finnish |
0420 | 420 | Arabic
See Arabic Support Considerations below. |
0437 | 37, 1140 | US English |
0500 | 500, 1148 | International (Latin 1) |
0886 | 937 (37, 835) | *Traditional Chinese |
0930 † | 930 (290, 300) | *Japanese Katakana Extended |
0939 † | 939 (1027, 300) | *Japanese Latin Extended |
9122 † | 9122 (290, 300) | *Japanese Katakana |
Character sets marked with an asterisk (*) are capable of mixed single-byte and double-byte character translation. EBCDIC CCSIDs in these rows indicate the mixed-byte CCSID first, followed by the single-byte, then double-byte Code Page Global Identifiers (CPGIDs) in parenthesis.
Other EBCDIC CCSIDs in parentheses reflect a 'non-Euro, Euro' pair for appropriate country codes.
For database applications using a DBMS server on Windows, use the table above.
Country Code
(MFCODESET) |
EBCDIC CCSIDs | Languages |
---|---|---|
1140 | 37,1140 | Dutch US English Portuguese |
1141 | 273,1141 | German (Austrian) German |
1142 | 277,1142 | Danish Norwegian |
1143 | 278,1143 | Swedish Finnish |
1144 | 280,1144 | Italian |
1145 | 284,1145 | Spanish |
1146 | 285,1146 | UK English |
1147 | 297,1147 | French |
1148 | 500,1148 | International (Latin 1) |
A code between 2000 and 9999 (except 9122) corresponds to a user-defined translation table. User-defined tables are created using the Codecomp utility.
If you are not using UK or US language settings, you must also set the codepage in your PC environment settings:
Syntax
Windows:
SET MFCSCFG=filename
UNIX:
MFCSCFG=filename
export MFCSCFG
Parameters
filename The name of the configuration file.
Example
Windows:
SET MFCSCFG=/home/mydir/mfclisrv.cfg
UNIX:
MFCSCFG=/home/mydir/mfclisrv.cfg
export MFCSCFG
Comments
The value of MFCSCFG is overridden by any value defined in the command line. If neither of the above yields a filename, the default filename mfclisrv.cfg is assumed, and is searched for in the current directory. If that in turn is not found, the default settings for the configuration entries are used.
Syntax
Windows:
SET MFLOGDIR=dirname
UNIX:
MFLOGDIR=dirname
export MFLOGDIR
Parameters
dirname The name of the directory for log files.
Example
Windows:
SET MFLOGDIR=/home/mydir/logs
UNIX:
MFLOGDIR=/home/mydir/logs
export MFLOGDIR
Specifies a configuration file for Language Environment (LE) run-time options.
Syntax
Windows:
SET MFLECONFIG=filename
UNIX:
MFLECONFIG=filename
export MFLECONFIG
Parameters
filename The file containing the LE run-time options you want to use.
Specifies the directories to be searched by all UNIX programs, including the run-time system, when finding executables to be run.
Syntax
PATH=pathname[:pathname]... export PATH
Parameters
pathname A directory to search for executables.
Example
PATH=$COBDIR/bin:$PATH export PATH
Syntax
TERM=name export TERM
Parameters
name The name of the terminal in the terminfo database.
Example
TERM=at386 export TERM
Specifies the directory to be searched by all UNIX programs, including the run-time system, for the UNIX system terminfo database.
Syntax
TERMINFO=pathname export TERMINFO
Parameters
pathname The name of a directory that contains the UNIX system terminfo database.
Comments
The UNIX system terminfo database is used by all UNIX applications that need to use a terminal. However, COBOL applications tend to make much fuller and sophisticated use of the terminal and require a fuller terminfo description than is required by typical UNIX applications such as vi. Some terminal capabilities, such as those set during the initialization of the terminal to control the use of function keys, commonly conflict with the needs of typical COBOL applications. In such cases, the terminal information required by COBOL can be stored in a separate terminfo database and referenced using COBTERMINFO.
Syntax
TMPDIR=pathname export TMPDIR
Parameters
pathname The directory used by UNIX applications for any temporary work files. Temporary work files can be created by COBOL utilities such as Cob or by the run-time system when it executes statements such as SORT. If you do not specify a directory, the system default directory is used.
Comments
You might need to use this environment variable if the run-time system needs to page data to disk when creating heaps or sorting.