Compiling
To compile OpenESQL applications that use a 64-bit Data Source Name (DSN) for 32-bit platforms, and for which you specify
the CHECK or DB compiler directive options, you must explicitly create a 32-bit DSN of the same name as the 64-bit DSN. Do
this using
the ODBC Data Source Administrator (32-bit). The execution process continues to use the 64-bit DSN.
This applies to Windows environments (local development) only.
Linking
If you use CHARSET(EBCDIC) when compiling COBOL code that contains SQL host variables that are of the display numeric type
defined as
XXXXXX, you must link to the
oesqlebc library to prevent link errors.
Windows:
You can either set up the link from the IDE and recompile, or run the required commands from a command prompt after compiling.
From the IDE, before compiling or recompiling:
- From the
Application Explorer view, right-click the project; then select
Properties from the context menu.
- Expand
Micro Focus > Build Configurations > Link; then click
Additional Link Files.
- Click
Add External Files.
- Browse to the
installDir\lib (for 32-bit) or
installDir\lib64 (for 64-bit) directory, where
installDir is the path to your
Enterprise Developer installation, which by default is
%ProgramFiles(x86)%\Micro Focus\Enterprise Developer.
- Double-click
oesqlebc.lib to select it and add it to the list; then click
OK.
From a command prompt, after compiling:
- Start an
Enterprise Developer command prompt. If you need instructions, see
To start an
Enterprise Developer command prompt.
- At the command prompt, switch to the directory that contains your COBOL code.
- Enter the following commands consecutively:
set lib=installDir\lib;%lib%
cbllink myapp.obj oesqlebc.lib
Where
installDir is the path to your
Enterprise Developer installation (by default, this is
%ProgramFiles(x86)%\Micro Focus\Enterprise Developer, and
myapp is the name of your COBOL object file.
UNIX:
On UNIX/Linux, the symbol
oesqleb2 is defined in the shared objects
coboesqlebc.so (32-bit) and
coboesqlebc64.so (64-bit). To resolve the link error, compile using the
-d flag as follows:
cob -x program.cbl -d {oesqleb2@coboesqlebc.so | oesqleb2@coboesqlebc64.so}
Where
program.cbl is the name of your COBOL program file.
Embedded SQL Statements
Any EXEC SQL statement that specifies a table or column name containing one or more special characters must have that table
or column name enclosed in quotes to prevent a preprocessor error. A special character is an ASCII character with a value
greater than 128 or a hexadecimal character with a value greater than x"80".
ODBC
When using Oracle's ODBC driver, array fetches and some scrolling fetches might produce inconsistent behavior if you change
the array size between fetches. To overcome this, build your application with SQL(NORESULTARRAY). When this is set, OpenESQL
performs single row fetches under the covers, bypassing this limitation.
OpenESQL ODBC Native Runtime
OpenESQL applications are optimized for performance by default, with OpenESQL now implicitly setting the BEHAVIOR compiler
directive to OPTIMIZED; with previous products, the BEHAVIOR compiler directive was implicitly set to UNOPTIMIZED. This change
can impact program behavior as follows:
- Programs that include the SET SCROLLOPTION or SET CONCURRENCY EXEC SQL statements fail to compile. For affected programs,
do one of the following:
- Before compiling, set the BEHAVIOR compiler directive to UNOPTIMIZED. While this is the simplest solution, we do not recommended
it due to the possibility of degraded performance.
- Remove all SET SCROLLOPTION and SET CONCURRENCY statements and, if necessary, modify the DECLARE CURSOR statement to include
appropriate parameters to yield the same behavior. For example, to elicit the same behavior as the SET SCROLLOPTION statement,
use the following DECLARE CURSOR statement:
EXEC SQL DECLARE cursorname SCROLL LOCK CURSOR FOR…
By default, cursors are forward and read only. If this is the desired behavior, you can safely remove the SET statements with
no further action required. However, we recommend as a matter of good practice to always include FOR READ ONLY or FOR UPDATE
in cursor declarations to ensure that the default behavior is always explicit. We recommended this solution.
- The OPTIMIZED setting does not make ambiguous cursors updateable. Therefore, applications that expect cursors to be updateable,
according to the default ANSI standards for Embedded SQL, are affected. In this case, we recommend that you set the BEHAVIOR
compiler directive option to ANSI.
- The OPTIMIZED setting does not assume scrollable cursors. Therefore, applications that expect cursors to be scrollable are
affected. In these cases, we recommend that you modify your DECLARE CURSOR statements to compensate, as specified above.
Important: If you do not want to take advantage of the performance gains provided by this change in implicit behavior, use the OpenESQL
Configuration Utility to change the implicit value of the BEHAVIOR compiler directive back to UNOPTIMIZED. For details, see
OpenESQL Embedded SQL Cursor Behavior and Performance.
PostgreSQL Recommendations
- PostgreSQL does not accept NULL date, time, or timestamp values from PIC X host variables. You must either use CAST(:hostvar as TIMESTAMP) in the SQL or use SQL TYPE TIMESTAMP in the application.
- PostgreSQL supports embedded NULL characters in binary columns only; it does not support embedded NULL characters in character
columns.
- When using PostgreSQL with ODBC for MBDT SQLTUB, PostgreSQL maps bytea data type to LongVarBinary or BLOB unless the default
behavior of the ODBC driver is changed.
- When using PostgreSQL with ODBC and a negative SQL code is returned to a calling application, PostgreSQL aborts transactions
implicitly unless you change the default behavior of the ODBC driver. In addition, PostgreSQL does not support the ODBC API
call SQLSetPos, which impedes the performance of updateable cursors.
To work around these shortcomings, consider modifying the psqlODBC driver Configuration Options. To do this:
- Invoke the
PostgreSQL ANSI or UNICODE ODBC Driver (psqlODBC) Setup dialog box.
- Click
Datasource.
- On
Advanced Options page 1, check
Use Declare/Fetch.
- Click
Page 2.
- On
Advanced Options page 2, set the
Level of rollback on errors option to
Statement, and uncheck
Updatable Cursors.
- Uncheck
bytea as LOG to resolve the behavior described in the third bullet point above.
- OpenESQL uses the PostgreSQL
oid field to support the use of FOR UPDATE cursors. Starting in PostgreSQL version 12, the internal
oid column is deprecated. Therefore, to use a FOR UPDATE cursor with PostgreSQL version 12 and later, you must first add an identity
column named
oid. For example:
EXEC SQL
alter table table-name add column oid smallint generated always as identity
END-EXEC
Note: You must also update existing
SELECT * FETCH statements from these tables to account for the returned
oid field.