Enterprise Server enables you to use special field types that only operate with supported
Micro Focus Terminal Emulators. These special fields are only supported for 3270 sessions in
Micro Focus Reflection Desktop and InfoConnect Desktop starting from version 17.0 Service Pack 1.
Note: These special field types can be disabled for non-Micro Focus Terminal Emulators by checking
Show All Data on Legacy Products. See below for more information.
The two special field types can be enabled by checking the
Required and the
Sensitive fields on the
Map Properties and
Mapset Properties dialog boxes. These two check boxes can be found in the
Mapatts group on the
Common Attributes tab.
To configure either field type, right-click the field in the
Micro Focus BMS Painter, this opens the
Field Properties dialog box. Click the
Micro Focus Enhanced tab and then check the options required:
- Required Field
- Check this to force the user to provide input to this required field. The field will be highlighted in red if the user fails
to enter data into the field when the form is submitted.
- Sensitive Field
- You can use this to specify the data redaction applied to the displayed field data:
- Show All Data
- All data is displayed. This is the default setting.
- Redact All Data
- All data is substituted for asterisks.
- Show Last 4 Characters
- Only the last 4 characters are displayed and the rest of the data is substituted for asterisks.
- Show First 6 Characters
- Only the first 6 characters are displayed and the rest of the data is substituted for asterisks.
- Show First 6 and Last 4 Characters
- Only the first 6 and last 4 characters are displayed and the rest of the data between is substituted for asterisks.
- Redact Options
- If you specify a
Sensitive Field option other than
Show All Data then you can specify any of the following additional options:
- Authenticate to View
- When checked, the field will be displayed with a View () button. Click the View button to open a Windows
User Account Control dialog box. Type an admin user name and password and then click
Yes to display the redacted data.
- Redact While Typing
- When checked, redaction occurs as the user types data into the field, replacing the characters for asterisks.
- Show All Data on Legacy Products
- When checked, non-Micro Focus Terminal Emulators that connect to
Enterprise Server applications that use the new field types will behave as if the new field attributes were not set. That is, required fields
will not force the user to enter data, and for sensitive fields the data will not be redacted.
Note: If this is not checked, then non-Micro Focus Terminal Emulators will error and you will not be able use the application being hosted in
Enterprise Server.