The program control statements supported by MFJSORT are listed below. The rules for coding the statements are identical to
the mainframe utility.
Note: MFJSORT emulates most major functions of IBM's DFSORT product; see
DFSORT and ICETOOL Emulation for more information.
Program Control Statements
-
ALTSEQ
- Specifies an alternate collating sequence for AQ control fields.
-
END
- Indicates the end of the program control statements. If omitted, MFJSORT reads to end of file.
-
INCLUDE
- Includes records from the input data set based on comparison testing of one or more fields in the input record. Supports substring
comparison and bit logic (bit operator and bit comparison) tests. You can specify up to 1024 conditional expressions.
-
INREC
- Rearranges input records before sorting or merging. Note that INREC may change the location of the control fields used by
SORT, MERGE, OUTFIL, OUTREC and SUM statements.
-
MERGE
- Defines a merge operation. You can include a
COPY request in the
MERGE statement. You can select portions of the input data sets for merging. You can define up to 32 control fields, but the total
length of the control fields must not exceed 1,024 bytes. You can request ascending or descending sequences for the following
control field types:
- AQ
- Alternate collating sequence.
- BI
- Binary.
- CH
- Character.
- CLO
- Signed numeric with leading overpunched sign.
- CTO
- Signed numeric with trailing overpunched sign.
- CSF
- Signed numeric with optional leading floating sign.
- CSL
- Signed numeric with leading separate sign.
- CST
- Signed numeric with trailing separate sign.
- FI
- Fixed integer.
- FL
- Floating point. Only 4-byte and 8-byte forms are supported. (COMP-1 and COMP-2).
- FS
- Signed numeric with optional leading floating sign.
- LS
- Signed numeric with leading separate sign.
- OL
- Signed numeric with leading overpunched sign.
- OT
- Signed numeric with trailing overpunched sign.
- PD
- Packed decimal.
- PD0
- Packed decimal, with sign and first digit ignored.
- TS
- Signed numeric with trailing separate sign.
- Y2B
- Two-digit, one-byte binary year data.
- Y2C
- Two-digit, two-byte character or zoned decimal year data.
- Y2D
- Two-digit, one-byte decimal year data.
- Y2P
- Two-digit, two-byte packed decimal year data.
- Y2S
- Two-digit, two-byte character or zoned decimal year data, with special indicators.
- Y2Z
- Two-digit, two-byte character or zoned decimal year data.
- ZD
- Zoned decimal.
-
MODS
- Specifies the names of the E15 and E35 exit programs. Other exits are not supported.
-
OMIT
- Excludes records from the input data set based on comparison testing of one or more fields in the input record. Supports substring
comparison and bit logic (bit operator and bit comparison) tests. You can specify up to 1024 conditional expressions.
-
OUTFIL
- Writes multiple output files. OUTFIL allows for extensions.
- Use the
INCLUDE,
OMIT and
SAVE operands to select the records to be included in each output data set. The
INCLUDE and
OMIT operands provide all of the capabilities of the
INCLUDE and
OMIT statements, while
SAVE can be used to select the records that are not selected for any other subset.
- The
OUTREC operand provides editing and control of the way numeric fields are presented with respect to length, leading or suppressed
zeros, symbols, and so on. Twenty six pre-defined editing masks (M0 to M25) are available, and user-defined masks can be created
using, for example, the
EDIT,
SIGNS and
LENGTH options. Use the
CHANGE option to select a character or hexadecimal string for output from a lookup table, based on a character, hexadecimal or bit
string as input.
- Use the
STARTREC and
ENDREC operands to select a range of records to be included in each output data set.
- Use the
SPLIT operand to distribute the records evenly among the output data sets.
- Use the operands
LINES,
HEADER1,
TRAILER1,
HEADER2,
TRAILER2,
SECTIONS and
NODETAIL, together with
OUTREC, to create complex reports including, for example, totals, maximums, minimums and averages for numeric input fields.
-
OUTREC
- Rearranges output records after sorting or merging. It can also insert literal variables into the output record. Supports
reformatting of records as well as the creation of formatted reports. Also supports arithmetic operations on input fields,
which can be further reformatted if needed.
-
Arithmetic operations can be done between two numeric fields using the operators
ADD (addition),
SUB (subtraction),
MUL (multiplication),
DIV (division). For example:
OUTREC FIELDS=(1,8,ZD,ADD,1,7,ZD,1X,2,5,PD,SUB,5,2,PD)
See note on
Sort/Merge Operations (MFJSORT) for restrictions.
-
RECORD
- Specifies record length information. Only the first value of this statement, which specifies the maximum record length, is
used; all other values are ignored. The logical record length of the input data set overrides any value specified by the
RECORD statement.
-
SORT
- Defines a sort operation. You can include a
COPY request in the
SORT statement. You can define up to 32 control fields, but the total length of the control fields must not exceed 1,024 bytes.
You can request ascending or descending sequences for the same control field types as described for the
MERGE statement.
-
SUM
- Produces only one output record for records with duplicate sort fields. Optionally, numeric fields in the duplicate records
can be summed in the output record. The sum operation can be done for the following control field types:
- AQ
- Alternate collating sequence.
- BI
- Binary.
- FI
- Fixed integer.
- FL
- Floating point. Only 4-byte and 8-byte forms are supported. (COMP-1 and COMP-2).
- FS
- Signed numeric with optional leading floating sign.
- PD
- Packed decimal.
- ZD
- Zoned decimal.
OVFLO Parameter
The
OVFLO parameter gives you control over the action (continue or terminate), type of message (informational or error), and return
code (0 or 16) that can be set during summary overflow. For example:
OPTION OVFLO=-----RC0-----
-----RC16-----
- RC0 - When summary fields overflow: issues overflow message, sets the return code to 0, and continues processing. RC0 is the
default value for the OVFLO parameter.
- RC16 - When summary fields overflow: issues overflow message, terminates processing, and gives a return code of 16.