RunUnitSwitches Property

MicroFocus.COBOL.RuntimeServices
Sets the switches for the programs executing in the RunUnit

Namespace:  MicroFocus.COBOL.RuntimeServices
Assembly:  MicroFocus.COBOL.RuntimeServices (in MicroFocus.COBOL.RuntimeServices.dll) Version: 1.2.3.4
Syntax

public string Switches { set; }

Property Value

Type: String

Implements

IRunUnitSwitches
Exceptions

ExceptionCondition
ArgumentExceptionIf StopRun method has already been invoked.
Examples

The following example shows a run unit (myRunUnit) being created and the COBOL class (switches) being called. When the class is called, it is implicitly instantiated and then run within the new run unit.

Finally the run unit is destroyed.

C#:

using MicroFocus.COBOL.RuntimeServices;
public class UseSwitches
{
   static void Main(string[] args)
   {
       RunUnit myRunUnit = new RunUnit();
       try
       {
          myRunUnit.Switches = "+0+2+3+4+6+8-3";
          myRunUnit.Call("switches");
       }
       finally
       {
          myRunUnit.StopRun();
       }
   }
}

COBOL:

cobol
program-id. useSwitches as "useSwitches".
 environment division.
 configuration section.
 repository.
   class cls-RunUnit as 
        "MicroFocus.COBOL.RuntimeServices.RunUnit" 
   .
 data division.
 working-storage section.
 01 myRunUnit object reference cls-RunUnit.

 procedure division.
 invoke cls-RunUnit "new" returning myRunUnit
    set myRunUnit::"Switches" to "+0+2+3+6+8-3+4"
 try
    invoke myRunUnit::"Call"("switches")
 finally
    invoke myRunUnit::"StopRun"()
 .
 end program useSwitches.

Where the called COBOL program is:

cobol
identification division.
  program-id.      switches.
  environment division.
  configuration section.
  special-names.
     switch-0 on status is sw-0,
     switch-1 on status is sw-1,
     switch-2 on status is sw-2,
     switch-3 on status is sw-3,
     switch-4 on status is sw-4,
     switch-5 on status is sw-5,
     switch-6 on status is sw-6,
     switch-7 on status is sw-7,
     switch-8 on status is sw-8.
  procedure division.
   if SW-0
        display "0 = ON"
   else
        display "0 = OFF"
   end-if
   if SW-1
        display "1 = ON"
   else
        display "1 = OFF"
   end-if
   if SW-2
        display "2 = ON"
   else
        display "2 = OFF"
   end-if
   if SW-3
        display "3 = ON"
   else
        display "3 = OFF"
   end-if
   if SW-4
        display "4 = ON"
   else
        display "4 = OFF"
   end-if
   if SW-5
        display "5 = ON"
   else
        display "5 = OFF"
   end-if
   if SW-6
        display "6 = ON"
   else
        display "6 = OFF"
   end-if
   if SW-7
        display "7 = ON"
   else
        display "7 = OFF"
   end-if
   if SW-8
        display "8 = ON"
   else
        display "8 = OFF"
   end-if
   goback.
See Also