A maximum of 500 PCBs can be defined in one PSB. There is no limit to the number of TP PCBs which can be defined, however,
only the first 99 can be referenced by an application program.
PCB TYPE=TP
Keyword
|
Values
|
Description
|
LTERM
|
*NAME
|
Supported but not edited
|
NAME
|
*NAME
|
Supported but not edited
|
ALTRESP
|
YES, NO
|
Ignored
|
SAMETRM
|
YES, NO
|
Ignored
|
MODIFY
|
YES, NO
|
Supported but not edited
|
EXPRESS
|
YES, NO
|
Ignored
|
PCBNAME
|
*NAME
|
Supported and edited
|
LIST
|
YES, NO
|
Supported and edited
|
Others
|
|
Any keyword not listed produces a warning message
|
Keyword
|
Values
|
Description
|
NAME, DBDNAME
|
*NAME
|
Supported and edited
|
PROCOPT
|
G, I, R, D, A, P, L, O, E
|
Supported and edited. Additional editing performed during PSBGEN Verify and when DL/I calls are made.
|
GS, LS
|
Supported as G and L
|
KEYLEN
|
All values
|
Supported. Edited during PSBGEN Verify
|
POS
|
S, M
|
Supported and edited
|
PROCSEQ
|
*NAME
|
Supported. Edited during PSBGEN Verify
|
PCBNAME
|
*NAME
|
Supported and edited
|
LIST
|
YES, NO
|
Supported and edited
|
SB
|
NO, COND
|
Ignored
|
Others
|
|
Any keyword not listed produces a warning message.
|
Keyword
|
Values
|
GSAM PCB Description
|
NAME, DBDNAME
|
*NAME
|
Supported and edited
|
PROCOPT
|
G, L
|
Supported but not edited during PSBGEN. For more information about GSAM databases, see the sections
GSAM Considerations in the chapter
For the Database Administrator (DBA) and
Unsupported DB Features in the chapter
Product Summary.
|
S
|
Ignored
|
PCBNAME
|
*NAME
|
Supported and edited
|
LIST
|
YES, NO
|
Supported and edited
|
Others
|
|