MFCWD02000 - MFCWD02019
Lists the PL/I debugger messages from MFCWD02000 through MFCWD02019.
MFCWD02000U Internal consistency error: invalid symbol table access. Possible compiler error. Correct all other errors. If this message persists, contact Micro Focus Support Line.
MFCWD02001U Symbol table overflow. The total number of internal symbol table pages exceeds the implementation's limit. Reduce the number and size of names, constants, extent-expressions, and argument or returns descriptors.
MFCWD02002U Symbol table overflow. Please contact Micro Focus Support Line.
MFCWD02003U Too many errors. The total number of diagnosed errors exceeds the %1 limit. processing aborted.
MFCWD02004U Internal consistency error: too many open files. The number of concurrently open files needed to continue processing exceeds the implementation's limit. If this message persists, contact Micro Focus Support Line.
MFCWD02005U Internal consistency error: internal value table overflow. Reduce the complexity of large expressions. Possible compiler error. Correct all other errors. If this message persists, contact Micro Focus Support Line.
MFCWD02006E Internal consistency error: attempt to free an already freed internal value. Possible compiler error. Correct all other errors. If this message persists, contact Micro Focus Support Line.
MFCWD02007U Internal consistency error: out of memory. Not enough heap storage is available from the system to continue processing. Correct all other errors. If this message persists, contact Micro Focus Support Line.
MFCWD02008U Internal consistency: unable to copy internal list. Attempt to copy an internal list failed when the new list could not be extended to the required size. Correct all other errors. If this message persists, contact Micro Focus Support Line.
MFCWD02009U Internal consistency error: invalid type for target conversion. An internal conversion failed when called with an unknown data type. If this message persists, contact Micro Focus Support Line.
MFCWD02010U Internal consistency error: invalid size for target conversion. An internal conversion to target representation failed when called with an invalid size value.
MFCWD02011U Internal consistency error: invalid size for host conversion. An internal conversion to host representation failed when called with an invalid size value.
MFCWD02012U Internal IL overflow. Unable to continue processing. Try breaking the compilation unit apart into smaller modules if possible, or reducing the number of executable statements. If this message persists, contact Micro Focus Support Line.
MFCWD02013U Unable to open file "%1". Include file nesting limit exceeded. Reduce the nesting level of included source files.
MFCWD02014U Internal heap storage exhausted. Unable to continue processing. Possible compiler error. Correct all other errors. If this message persists, contact Micro Focus Support Line.
MFCWD02015U Internal consistency error. Possible compiler error. Correct all other errors. If this message persists, contact Micro Focus Support Line.
MFCWD02016U Internal consistency error. Possible compiler error. Correct all other errors. If this message persists, contact Micro Focus Support Line.
MFCWD02017W Internal consistency error. Possible compiler error. Correct all other errors. If this message persists, contact Micro Focus Support Line.
MFCWD02018U Internal consistency error. Unable to open existing node list file. Possible compiler error. Correct all other errors. If this message persists, contact Micro Focus Support Line.
MFCWD02019W Internal consistency error. Unable to create temp file for new node list. Possible compiler error. Correct all other errors. If this message persists, contact Micro Focus Support Line.
Parent topic:
MFCWD02000 - MFCWD06009