The <opt> option is required in OSVS COBOL programs to provide a length specification. Note that it is optional in VS COBOL II programs
since it can be defaulted to the LENGTH OF construct.
- System Action:
- An Unsupported Function abend is generated for the EXEC CICS statement and an ERROR is raised.
- Resolution:
- Correct the EXEC CICS statement by adding the required option and specifying an appropriate argument for the length.
- Module:
- cicsprep (dfhxc2pc)
- Destination:
- Source Listing, .TRL file, STDOUT