Compatible Upgrade Process

Important: Ensure that you have read the corresponding Patch Update ReadMe to confirm that the compatible upgrade process is appropriate.

For the compatible upgrade process, enterprise server regions running with different product versions can temporarily coexist while the update is being applied. This avoids the need to completely stop the PAC from running.

  1. Stop new client connections to Region 1. This can be done by disabling the enterprise server listeners and/or modifying the load balancer configuration. See Managing client connections during a PAC upgrade for more information.
  2. Stop Region 1. Use ESCWA or casstop to gracefully stop enterprise server region. This will terminate any existing client connections. You can check active client connections on the CLIENT LIST page. In the navigation tab, click the required enterprise server region and then click MONITOR > Client.
    Note: It can take some time to stop an enterprise server region which has active client connections. This can result in a Not Responding message being displayed before it is reported as Stopped. Stopping an enterprise server region with active client connections might result in errors in the communications log.
  3. Apply the product upgrade to the Region 1 machine.
  4. Restore the Micro Focus Directory Server (MFDS) configuration backup to the Region 1 machine.
    Note: This is not required for Enterprise Developer 6.0 and later, as the Patch Update installer will automatically preserve the MFDS configuration.
  5. Start Region 1 in warm mode. In the ESCWA Region Start Options dialog box, uncheck Cold Start before starting the enterprise server region. Once started, ensure that the enterprise server region joins the PAC. You will see the following or similar message in the console log:
    CASSI1432I Joining PAC MYPAC. 14:46:19

    Record layout compatibility checks are preformed and if incompatible records are found the enterprise server region is unable to start. The following console message is displayed:

    PA2105S Region cannot be started because an incompatible record <record type> was found in the PSOR

    Where <record type> can be TST, CSA, DCT, PCT, FCT and so on.


    Compatible Upgrade Process - Region 1 Upgrade
  6. Enable client connections for Region 1 via the load balancer and/or the enterprise server listeners. See Managing client connections during a PAC upgrade for more information.
    Note: You might not want to perform this step at this point if you are upgrading the enterprise server regions in groups. This is to minimize disruption to connecting clients.
  7. Repeat steps 1 through 6 for Region 2.

    Both enterprise server regions have now been upgraded.


    Compatible Upgrade Process - Region 2 Upgrade
Note: At this point, all enterprise server regions in the PAC are upgraded and running. However, the PAC is running with the environment variable ES_PAC_MIN_COMP_CHECK=YES which reduces the checking of version levels being used. This is not an ideal long-term state for the PAC. If this is the case, you might want to upgrade using steps specified in the Incompatible Upgrade Process topic.