Restriction: This topic applies only when the AppMaster Builder AddPack has been installed, and applies only to Windows platforms.
File Contents:
Edit APIMSIN to control the following information in IMS DB calls:
Prologue generation.
EJECTs.
Color, Blink, Reverse Video, Underscore switches.
System Service Calls (IM-STAT, IM-LOG, IM-ROLL, IM-ROLB).
GSAM RSA calls.
DB-PROCESS call loop limit flag, &VS-IMS-LOOP-MAX (default 100); you can change the limit number or disable the check for
the limit.
Generation of calls to the A1MVCL run-time module. The value of the Customizer control variable &CODE-A1MVCL-INLINE controls
whether the Customizer generates calls to the A1MVCL run-time module to move blocks of data to a target location from a source
location or generates inline COBOL MOVE statements instead.
Value
Generates
Not defined
Calls to A1MVCL
NO
Calls to A1MVCL (default)
YES
Inline COBOL MOVE statements
Note: You can specify a value for &CODE-A1MVCL-INLINE in this CNTL file or define &CODE-A1MVCL-INLINE and its value within a program.
If you define &CODE-A1MVCL-INLINE and its value within a program, the value specified in the program overrides the value specified
in APIMSIN.