This table shows return codes from MFBSIJCL.
Return Code | Description |
---|---|
200 |
CASSUB parameters missing
The minimum parameters required to execute cassub not specified or can't be configured from mfbsi.cfg (-r/-l/sTCP:... -j|-x) |
201 | Too many parameters on the command line
More than 35 parameters found on the mfbsijcl command line |
202 | Unknown command line parameter detected |
203 | Scheduler jobLog not assigned (SJobID) |
204 | MFBSI_DIR environment variable not set |
205 | MFBSI_DIR defines an invalid dir/folder |
206 | Invalid numeric value for TimeOut |
207 | JCL UserExit failed to execute / Rc <> 00
An mfbsi user exit returns with Rc not equal to zero |
208 | JES/JCL error detected
Job has been submitted but JES detected a JCL error |
209 | Job submission failed (See
JobLog output)
JCL member not found. See message JCLSI0003I in mfbsi jobLog for details |
210 | JobConcluded signal event not returned
ES Event Manager user-exit (mfbsiemx) didn't return the event "job concluded" |
211 | Job ended, no numeric RC returned
Contact Micro Fous Support |
212 | CommandLine parameters missing
No commandLine parameters found when executing mfbsijcl |
213 | Configuration parameter unknown
Invalid/unknown commandLine parameters found when executing mfbsijcl |
214 | Unable to configure JCL to submit parameter
The cassub parameter "-j|-x" can't be determined |
215 | TYPRUN=SCAN: scan successful |
216 | TYPRUN=SCAN: scan failed |
217 | JCL UserExit program missing or not found
Module name specified in JCLexit=??? can't be loaded Windows: ???.int/???.gnt/???.dll UNIX: ???.int/???.gnt/???.so|???.sl |
218 | Terminate user-exit program missing or not found
Module name specified in TerminateExit==??? can't be loaded |
219 | SEP execution process hard killed |
220 | Restart for Job failed
Job to restart not found in ES/JCL ES_JES_RESTART=Y and/or MF_UCC11=Y missing in ES Configuration Information |
221 | Unable to call module "MFBSIPRM"
Internal error. Contact Micro Focus Support |
222 | Error during skeletal parameter(s) substitution
Internal error. Contact Micro Focus Support |
223 |
MFBSI.cfg error: "SkelProcessType" unknown
Internal error. Contact Micro Focus Support |
224 |
More than 10 ISPSLIB paths Internal error. Contact Micro Focus Support |
225 | Server crashed/killed when job was waiting for execution
mfbsijcl is unable to correctly contact the JCL region to get the job state |
226 | SYS/USR-ABEND-RC=nnn in MFBSI.cfg not numeric or greater than 199 |
227 | JESYSMSG-RC=Y(es) requires parameter JESYSMSG
The parameter "JESYSMSG-RC=Y(es)" should no longer be used |
228 | Server crashed/killed when job was running
mfbsijcl is unable to correctly contact the JCL region to get the job state |
229 | Job state unknown or inconsistent. Check Job status via SEE Web admin
mfbsijcl is unable to correctly determine the job state (Information from the Event Manager user-exit not in sync with job state) |
230 | Max number of parameters to substitute reached
When using parameter(s) substitution, maximum 500 parameters are allowed On the command line, maximum 15 pairs ParamName/ParamValue are allowed |
231 | Parameter file used for variable substitution not found
A file to be used with parameters substitution can't be found |
232 | mfbsijcl execution cancelled by a SIGTERM/Break signal
mfbsijcl has been interrupted by a soft kill (e.g. Ctrl+C) |
233 | Submitted job cancelled before execution
A job waiting for execution in ES has been cancelled |
234 | MFBSI Control-M Post-Processing Handler Error
Internal error. Contact Micro Focus Support |
235 | Invalid special file name for
mfbsi.cfg
The alternate path of mfbsi.cfg (default in MFBSI_DIR) is incorrect |
236 | Special file name for "mfbsi.cfg" not found
The alternate mfbsi.cfg can't be found |
237 | Invalid EMX-Timout parameter value. See
mfbsi.cfg
Internal error. Contact Micro Focus Support |
241 | MFBSISEC user-exit module not found |
242 | Invalid MFBSIEMX version level. MFBSIEMX v3. is required
An old version of the Event Manager user-exit is used |
243 | In
MFBSI_DIR, "regionName.Started" not found
ES/JCL region not started or not configured for MFBSI See ES "Configuration Information" MFBSI_DIR=… or ES_EMP_EXIT_#=mfbsiemx missing # specifies the Event Manager user-exit sequence number (starting from 1. Max 9.) |
244 | Unexpected "Job Concluded" signal received from Enterprise Server during job execution.
The semaphore file JOB?????.sem does not reflect the end of the job. Nevertheless, the Enterprise Server JCL engine considers the job as ended. You need to check console.log for any messages concerning the Enterprise Server Event Manger and mfbsiemx. Then, ensure that the file system disk space used by MFBSI_DIR and any other Enterprise Server components is not full. |