Specifies whether logical or physical cancels are used.
Restriction: These tunables are supported for native COBOL only.
Syntax:
>>-----set default_cancel_mode---.-0-.-----------><
+-1-+
+-2-+
Parameters:
0
|
Physical cancels: any program canceled during run-time will be freed from memory, making more memory available.
|
1
|
Compatibility mode. As Logical cancels mode, except that
.dll files or shared objects are physically canceled. This option is present for compatibility with older products.
|
2
|
Logical cancels: any program canceled during run-time will not be freed from memory. The program is available to be reused
and hence the performance of CALL/CANCEL statements is greatly increased.
|
As far as your program is concerned, logical and physical cancels behave identically.
Properties:
Default:
|
2
|
IDE equivalent:
|
Use the
Application.config file of the project - right-click the file in Solution Explorer and click
Open, then select the
Run-time Configuration tab.
|