Access Manager 5.1.0.1 supersedes Access Manager 5.1.
If you have suggestions for documentation improvements, click comment on this topic at the top or bottom of the specific page in the HTML version of the documentation posted on the Documentation page.
For information about the Access Manager support life cycle, see the Product Support Life Cycle page.
This release includes the following software fixes:
Component |
Bug ID |
Issue |
---|---|---|
SAML2.0 |
602434 |
Administration Console SAML 2.0 service provider configuration menu returns the global SAML metadata instead of service provider specific metadata. |
NIDS-Authentication |
604444 |
After upgrading to Access Manager 5.1, the service provider displays incorrect signing and encryption certificates. |
NIDS-SAML2.0 |
607120 |
After upgrading to Access Manager 5.1, Liberty and SAML2.0 identity provider metadata is modified. |
NIDS-SAML2.0 |
608258 |
After upgrading to Access Manager 5.1, IDP server returns Request Denied message on an unsigned SAML2.0 authentication request. |
Administration Console |
619051 |
After upgrading to Access Manager 5.1, Administration Console does not allow adding an attribute within a set without defining a remote attribute name. |
NIDS-Authentication |
636116 |
Deleting an identity server role that contains a contract, class, or method without disabling it on the identity cluster does not return an error until the identity server is restarted, and this causes server failure. |
Administration Console |
639083 |
Enabling Session Assurance displays error. |
Administration Console |
646003 |
After upgrading to Access Manager 5.1, Advanced File Configurator files are empty. |
Administration Console |
646005 |
New Attribute Set cannot have _ (underscore) as Set Name. |
NIDS-WS-Fed |
646188 |
Office 365 WSFED application connector fails to save application. |
NIDS-User Stores |
646205 |
When the user is not in the first eDirectory context, login fails. |
NIDS-OAuth2.0 |
648005 |
The Save option is disabled even after updating the OAuth2.0 client registration details. |
Access Manager 5.1.0.1 resolves the following security issue:
Access Manager supports RADIUS authentication class. RADIUS client is updated to consistently send the Message-Authenticator (MA) attribute at the beginning of all RADIUS messages when the MessageAuthenticatorAttribute is set to true at Method configuration, CVE-2024-3596.
For more information, see Configuring Authentication Methods in the NetIQ Access Manager CE 24.2 (v5.1) Administration Guide.
Before upgrading, verify that the version number of the component is indicated as 5.1.0.0-272. To verify the version number, perform the following steps:
On the Home page, click Troubleshooting > Version.
Verify that the Version field lists 5.1.0.0-272.
IMPORTANT:In a cluster setup, ensure that you install the patch on each node of the Access Manager setup.
The patch helps in upgrading to the latest version of Access Manager with ease.
If you have multiple components installed on the same system, the patch installation process takes care of updating all the binaries of these components. For example, if you have both Identity Server and Administration Console installed on a system, installing the patch takes care of updating the binaries of Identity Server and Administration Console.
NOTE:This patch update is not required for Analytics Server.
IMPORTANT:Ensure that you are currently on Access Manager 5.1 before upgrading to Access Manager 5.1.0.1.
You need to procure the license key from the Software License and Download portal to register to 5.1.
You can upgrade to Access Manager 5.1.0.1 by using the proceeding steps. This requires few manual interventions to continue the upgrade process.
Extract the patch file by using the unzip AM_5101.zip command.
After extraction, the following files and folders are created in the AM_5101 folder:
Table 1 Files and folders created in the AM_5101 folder after extracting the patch installer ZIP file
File/Folder Name |
Description |
---|---|
rpm |
Contains rpm files for the patch. |
installPtool.sh |
Script to install the patch and the patch tool. |
installPatch.sh |
Script to install the patch tool and the updated binaries. |
Log in as the root user.
Go to the location where you have extracted the patch files.
Run the installPatch.sh command.
This command installs the patch and the bundled binaries.
NOTE:To manage the Access Manager patch file, refer to Managing the Patch.
If the patch is already installed, the installer exits with a message.
After the patch is installed, go to the following folder:
/opt/novell/nam/patching/bin
Use the following options to manage the Access Manager patch file:
Option |
Description |
Command on Linux server |
---|---|---|
-qa |
Lists all installed patches. |
./patch -qa |
-q |
Lists details of an installed patch. |
./patch –q Example:./patch –q P1-22 |
-i |
Installs a patch. During installation of a patch, all running services are stopped temporarily. After a patch is installed, all services are restarted and details of the operation are written to log files. |
./patch –i <location and patch name> Example:./patch –i /opt/novell/nam/Patches/AM_5101/AM_5101-22.patch |
-e |
Removes an installed patch. The patch maintains content relationship among patches. So, if you have installed patch 1 and patch 2, patch 1 cannot be removed without removing patch 2. This is because patch 2 contains details of patch 1 as well.During the patch process, all the running services are stopped temporarily. |
./patch –e <patch name> Example:./patch –e P1-22 |
-qpl |
Lists details of a patch that is not installed. If you want to view the changes that are included in the patch file without installing it on your server, use this option |
./patch –qpl <location and patch name> Example:./patch –qpl /opt/novell/nam/Patches/AM_5101/ AM_5101-22.patch |
-v |
Verifies integrity of a patch. |
./patch –v <location and patch name> Example:./patch –v /opt/novell/nam/Patches/AM_5101/ AM_5101-22.patch |
-t |
Verifies if services can be restored by the installer. Use this option to stop/start all services after the installation of patch. |
./patch –t <location and patch name> Example:./patch –t /opt/novell/nam/Patches/AM_5101/ AM_5101-22.patch |
After upgrading, verify that the version number of the component is indicated as 5.1.0.1-22. To verify the version number, perform the following steps:
On the Home page, click Troubleshooting > Version.
Verify that the Version field lists 5.1.0.1-22.
Copyright 2009 - 2024 Open Text.
The only warranties for products and services of Open Text and its affiliates and licensors (“Open Text”) are as may be set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Open Text shall not be liable for technical or editorial errors or omissions contained herein. The information contained herein is subject to change without notice.